105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14499958

E GI IV,ELECTRICAL,ELECTROCUTED,PLUMBING,ELECTRIC CORD,METAL PIPE,ELEC EQUIPMENT--MISC

Event
E GI IV,ELECTRICAL,ELECTROCUTED,PLUMBING,ELECTRIC CORD,METAL PIPE,ELEC EQUIPMENT--MISC
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14499958
Report ID
523400

Event description

ELECTRIC SHOCK - CONTACT WITH LIVE PARTS THRU PIPE CUTTER

Investigation abstract

AN EMPLOYEE OF A WATER SOFTENER FIRM WAS INSTALLING A WATER SOFTENER AT A MOBILE HOME. HE WAS KNEELING ON WET GROUND, USING A PIPE CUTTER TO CUT A COPPER WATER PIPE. A PIPE HEATER CORD WAS WRAPPED AROUND THE PIPE WHERE IT WAS BEING CUT. THE HEATER CORD WAS PLUGGED INTO AN OUTLET 2 FEET AWAY FROM THE EMPLOYEE. IN CUTTIN G THE PIPE, THE EMPLOYEE CUT INTO THE 120-VOLT HEATER CORD AND WAS ELECTROCUTED. THE EMPLOYEE WAS FOUND SOME TIME LATER, AND CURRENT WAS STILL PASSING THROUGH H IM WHEN THE RESCUE SERVICE ARRIVED.

Victim

  1. #1 Fatality Age 41 M

    Nature of injury
    10
    Part of body
    4
    Event type
    13
    Source
    1
    Occupation code
    585
    Human factor
    1
    Environmental factor
    13
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.