105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #848523

FUSE,E GI IV,ELECTRICAL,ELECTROCUTED,ELECTRICAL WORK,INTERLOCK,LOCKOUT,ELECTRICAL CABINET

Event
FUSE,E GI IV,ELECTRICAL,ELECTROCUTED,ELECTRICAL WORK,INTERLOCK,LOCKOUT,ELECTRICAL CABINET
Linked inspection
No inspection record linked to this accident's victims.
Summary number
848523
Report ID
524200

Event description

ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

Investigation abstract

AN EMPLOYEE WAS CHANGING A FUSE IN THE CONTROL PANEL OF GRUENBERG OVEN. HE REACH ED BEHIND THE FUSE TO HOLD A BOLT IN PLACE WHILE HE LOOSENED A NUT. HE WAS ELECT ROCUTED WHEN HE CONTACTED THE 480-VOLT CIRCUIT PARTS. THE INTERLOCK FOR THE DOOR EITHER MALFUNCTIONED OR WAS BY-PASSED, LEAVING THE CIRCUIT PARTS INSIDE THE CON TROL PANEL ENERGIZED. THE EMPLOYEE HAD NOT TESTED THE CIRCUIT TO ENSURE THAT IT WAS, IN FACT, DEENERGIZED.

Victim

  1. #1 Fatality Age 37 M

    Nature of injury
    10
    Part of body
    12
    Event type
    13
    Source
    15
    Occupation code
    999
    Human factor
    18
    Environmental factor
    18
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.