105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #976613

AMPUTATED,DIE CUTTING PRESS,FINGER,UNGUARDED LIVE PARTS,DIE GUARD,PRESS OPERATOR,MECH MALFUNCTION

Event
AMPUTATED,DIE CUTTING PRESS,FINGER,UNGUARDED LIVE PARTS,DIE GUARD,PRESS OPERATOR,MECH MALFUNCTION
Linked inspection
No inspection record linked to this accident's victims.
Summary number
976613
Report ID
551800

Event description

EMPLOYEE'S THREE FINGERS AMPUTATED WHEN CAUGHT IN DIE PRESS

Investigation abstract

On June 26, 1989, Employee #1 was working at a Rousselle No. 4W, 40-ton mechanic al power press where she was stamping out four parts in a 26.5 by 29.5 plastic p anel. There was 2.785 opening between the dies and the press, which was operated by hand. Employee #1 was removing the second stamped part from the die with her hands when the press double tipped closing dies on four fingers. Although the E mployee #1's ring finger was reattached, three other fingers were amputated.

Victim

  1. #1 Hospitalized Age 63 F

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    9
    Environmental factor
    1
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.