105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #980524

PULL BACK DEVICE,DIE,AMPUTATED,INADEQUATE MAINT,POWER PRESS,FINGER,EQUIPMENT FAILURE,TWO-HAND CONTROL,POINT OF OPERATION,HAND

Event
PULL BACK DEVICE,DIE,AMPUTATED,INADEQUATE MAINT,POWER PRESS,FINGER,EQUIPMENT FAILURE,TWO-HAND CONTROL,POINT OF OPERATION,HAND
Linked inspection
No inspection record linked to this accident's victims.
Summary number
980524
Report ID
551800

Event description

Employee's fingers amputated in malfunctioning press

Investigation abstract

At approximately 4:15 p.m. on July 8, 1989, Employee #1, a processor for Modine Manufacturing Company in Logansport, IN, was placing a part into the dies of a J ohnson 75 ton mechanical press, serial #M-1003. The press double tripped. Althou gh Employee #1 was using pull out equipment and two-hand control buttons, his le ft hand was caught in the point of operation. The employee's index and middle fi ngers were amputated, and his hand sustained a contusion. The mechanical press w as in bad condition and the anti-repeat mechanism failed. In addition, the pull out device was defective.

Victim

  1. #1 Hospitalized Age 27 M

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    9
    Environmental factor
    3
    Hazardous substance
    8130
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.