ERIE, PENNSYLVANIA—
Fox Construction, Inc.
Ignition of vapors, gases, or liquids · Heat (thermal) burns, unspecified
Final narrative
While working in a ditch, an employee cut a test header off a piece of steel pipe. The test header was being lifted out of the ditch when it tipped to the side and some methanol, which had been used to clean the pipe, leaked out and onto the employee's legs. The methanol ignited and caught the employee's legs on fire. The employee was hospitalized with leg burns.
Similar incidents · Same event type
FORT MYERS, FLORIDA—
Sam Galloway Ford, Inc.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
MOULTRIE, GEORGIA—
Canfor Southern Pine, Inc.
An employee was welding on a rack when sparks ignited residual diesel on his pants. The employee sustained first-, second-, and third-degree burns.
WILLACOOCHEE, GEORGIA—
Freedom Trailers, LLC
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
PENSACOLA, FLORIDA—
Flora-Bama Management, LLC
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
CARTERSVILLE, GEORGIA—
JANUS INTERNATIONAL GROUP, LLC
An employee was using a torch when a hole in the oxygen line leaked gas that then ignited. The employee sustained burns to the left palm and wrist.