Placon Corporation

Caught in or compressed by equipment or objects, unspecified · Amputations

An employee was changing a motor and gearbox on a thermoforming machine. During the process, the shaft stayed up in the platen. While he was positioning the motor using his hands, the shaft released, causing the table to go to the lowest position and the arms to raise up. This created a scissor-like motion, which amputated the employee's right ring fingertip.

Amputation Fingertip(s) Extruding, injecting, forming, molding machinery, n.e.c.

N. S. Giles Foundations, Inc.

An employee was changing mud cups in the hopper cylinders of a concrete pump truck. The cylinders moved and three of the employees fingers were amputated.

Weld Mech, Inc.

An employee was standing on the rig floor next to a polishing unit. His hand was placed on the polishing unit when the pump was lowered, resulting in amputation of their right thumb, ring, and middle fingertips.

Axium Packaging LLC

An employee was using air to blow out the air wash to the blender and grinder station. As the employee reached to verify that the air wash was clean, the unit pinched and amputated their fingertip.

PanTerra Energy

An employee was retrieving a lost drill pipe with a lifting bail when their left thumb got pinched between the table and handle of the lifting bail while trying to re-thread the pipe to lift it out. The employee suffered an amputation to the left thumb.

Graphic Packaging International

An employee was removing a core chuck from a stationary roll when their right ring finger was pinched between the chuck and the roll. The employee's fingertip was amputated.