Weston, WI —
OSHA Injury Report: MMC- Weston
Injury · Other recordable case
At a glance
On , an injury at MMC- Weston in Weston, WI 54476 resulted in other recordable case. Employee was laboratory Technical Assistant Regional Float in general medical and surgical hospitals.
Where did this happen?
- Establishment
- MMC- Weston
- Parent company
- Marshfield Clinic Healthcare System
- Street
- 3400 Ministry Parkway
- City
- Weston
- State
- WI
- ZIP
- 54476
- On-site location
- PHLEBOTOMY STATION
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
UNABLE TO ENGAGE SAFETY AFTER USE OF BUTTERFLY NEEDLE WENT TO PLACE CONTAMINATED NEEDLE IN SHARPS CONTAINER AND GOT STUCK WITH UNPROTECTED NEEDLE WHEN WING GOT HOOKED ON CONTAINER.
What happened
WHILE PUTTING USED BUTTERFLY NEEDLE INTO SHARPS CONTAINER AFTER THE SAFETY FAILED TO ENGAGE POKED FINGER
Injury or illness
RIGHT RING FINGER CONTAMINATED NEEDLE STICK
Object or substance involved
CONTAMINATED BUTTERFLY NEEDLE STICK
Summary line
CONTAMINATED NEEDLE STICK TO RIGHT HAND RING FINGER MIDDLE JOINT PALMER SURFACE
Employee and industry
- Job description
- Laboratory Technical Assistant Regional Float
- SOC code
- 9999 — Uncoded
- NAICS code
- 622110 — General medical and surgical hospitals
- NAICS vintage
- 2012
- Avg employees
- 491
- Total hours worked
- 698278
- EIN
- 810977948
- Establishment ID
- 902449
- Employer case #
- AAAC000000
When (timing detail)
- Date of incident
- Shift started
- 7:30
- Time of incident
- 14:19
- Filing year
- 2024
- Submitted
- 31JAN2025:15:11:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.