Corsicana, TX —
OSHA Injury Report: Guardian Corsicana
Injury · Days away from work
At a glance
On , an injury at Guardian Corsicana in Corsicana, TX 75109 resulted in days away from work. Employee was coater in flat glass (e.g., float, plate) manufacturing.
Where did this happen?
- Establishment
- Guardian Corsicana
- Parent company
- Guardian Industries Inc.
- Street
- 3801 South US 287
- City
- Corsicana
- State
- TX
- ZIP
- 75109
- On-site location
- Coater Unloading Line
What was the outcome?
- Outcome
- Days away from work (code 2)
- Type
- Injury (code 1)
- Days away from work
- 35
Before the incident
Employee was assisting the Load End operator to set up racks to load glass lites in the robot cell area to be processed.
What happened
After worker helped set up racks he was standing near a space heater and unknowingly his clothing came into contact with a space heater and caught on fire.
Injury or illness
Burn to lower back
Object or substance involved
Small portable space heater
Summary line
EE came in contact with small heater clothing caught on fire causing burn to lower back
Employee and industry
- Job description
- Coater
- SOC code
- 9999 — Uncoded
- NAICS code
- 327211 — Flat glass (e.g., float, plate) manufacturing
- NAICS vintage
- 2012
- Avg employees
- 222
- Total hours worked
- 519768
- Establishment ID
- 820990
- Employer case #
- 6
When (timing detail)
- Date of incident
- Shift started
- 8:00
- Time of incident
- 10:57
- Filing year
- 2024
- Submitted
- 06FEB2025:22:30:00
Source