OSHA Injury Report: DuPage Machine Products, Inc

Injury · Days away from work

On , an injury at DuPage Machine Products, Inc in Bloomingdale, IL 60108 resulted in days away from work. Employee was operator in precision turned product manufacturing.

Establishment
DuPage Machine Products, Inc
Parent company
DuPage Machine Products
Street
311 Longview Drive
City
Bloomingdale
State
IL
ZIP
60108
On-site location
Auxiliary Department
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
9
Days restricted or transferred
94

Broaching armature on [REDACTED] broach machine.

While broaching armatures on [REDACTED] the operator stuck her finger between the broach and the Armature being broached after actuating the cycle with the 2 handed safety switch. This was done within the 1.5 sec cycle of the broach. The operator reported this resulted from adjusting oil lines during the cycle though through review we determined this could not have caused the accident. The operator did not give additional details on what caused this incident.

An avulsion of the left index finger. The operator was driven to the emergency room of Midwest Hand Surgery SC for treatment. We were told the injury was cosmetic not functional. The operator missed 9 days of work and was on restricted duty until 9 11 24.

Finger pinched between Broach and armature

An avulsion of the left index finger

Job description
Operator
SOC code
51-9199 — Production Workers, All Other
NAICS code
332721 — Precision turned product manufacturing
NAICS vintage
2012
Avg employees
221
Total hours worked
341360
EIN
362681281
Establishment ID
73944
Employer case #
0524
Date of incident
Shift started
17:00
Time of incident
22:15
Filing year
2024
Submitted
17FEB2025:21:00:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.