Waller, TX —
OSHA Injury Report: Premier Coil Solutions
Injury · Other recordable case
At a glance
On , an injury at Premier Coil Solutions in Waller, TX 77484 resulted in other recordable case. Employee was after Market Sales Director in oil and gas field-type drilling machinery and equipment (except offshore floating platforms) manufacturing.
Where did this happen?
- Establishment
- Premier Coil Solutions
- Parent company
- Premier Coil Solutions
- Street
- 18993 GH Circle
- City
- Waller
- State
- TX
- ZIP
- 77484
- On-site location
- Shop floor Cell C3
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Employee was checking for hydraulic leaks on a trailer.
What happened
The pilot operated valve actuator handle was stuck due to bolts holding the valve on the bracket being too long. The handle freed itself after enough pressure caused the handles to shear the bolts. The handle moved striking the back of the employee’s left hand with the handle of the actuator.
Injury or illness
Cuts to the index middle and ring finger of employee’s left hand.
Object or substance involved
pilot operated valve actuator handle
Summary line
A pilot operated valve actuator handle struck the back of the employee’s left hand. This caused cuts to the index middle and ring finger of employee’s left hand.
Employee and industry
- Job description
- After Market Sales Director
- SOC code
- 11-2022 — Sales Managers
- NAICS code
- 333132 — Oil and gas field-type drilling machinery and equipment (except offshore floating platforms) manufacturing
- NAICS vintage
- 2022
- Avg employees
- 58
- Total hours worked
- 115048
- EIN
- 452291662
- Establishment ID
- 279371
- Employer case #
- 23-2
When (timing detail)
- Date of incident
- Shift started
- 8:00:00.000
- Time of incident
- 10:30:00.000
- Submitted
- 09JAN24:19:23:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.