2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Premier Coil Solutions

Injury · Other recordable case

On , an injury at Premier Coil Solutions in Waller, TX 77484 resulted in other recordable case. Employee was after Market Sales Director in oil and gas field-type drilling machinery and equipment (except offshore floating platforms) manufacturing.

Establishment
Premier Coil Solutions
Parent company
Premier Coil Solutions
Street
18993 GH Circle
City
Waller
State
TX
ZIP
77484
On-site location
Shop floor Cell C3
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

Employee was checking for hydraulic leaks on a trailer.

The pilot operated valve actuator handle was stuck due to bolts holding the valve on the bracket being too long. The handle freed itself after enough pressure caused the handles to shear the bolts. The handle moved striking the back of the employee’s left hand with the handle of the actuator.

Cuts to the index middle and ring finger of employee’s left hand.

pilot operated valve actuator handle

A pilot operated valve actuator handle struck the back of the employee’s left hand. This caused cuts to the index middle and ring finger of employee’s left hand.

Job description
After Market Sales Director
SOC code
11-2022 — Sales Managers
NAICS code
333132 — Oil and gas field-type drilling machinery and equipment (except offshore floating platforms) manufacturing
NAICS vintage
2022
Avg employees
58
Total hours worked
115048
EIN
452291662
Establishment ID
279371
Employer case #
23-2
Date of incident
Shift started
8:00:00.000
Time of incident
10:30:00.000
Submitted
09JAN24:19:23:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.