Longview, TX —
OSHA Injury Report: Invista Longview TX
Injury · Other recordable case
At a glance
On , an injury at Invista Longview TX in Longview, TX 75602 resulted in other recordable case. Employee was boilermaker.
Where did this happen?
- Establishment
- Invista Longview TX
- Parent company
- Turner Industries Group LLC
- Street
- 2290 Callahan Rd.
- City
- Longview
- State
- TX
- ZIP
- 75602
- On-site location
- 131010724508 Flint Hills Longview TX Unit 118
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Removing bolts to roll expansion joint
What happened
Work group was tasked with completing a 16 inch expansion joint make up above pump CCW on the 12th floor in the [REDACTED] Unit The piping system included a plate support bolted within flange bolts of a 16 inch flange While installing the bottom spool above the support it was determined that the support bolts had to be removed so that the spool would have the clearance to be installed While removing the last bolt going through the plate support the bottom flange shifted to the south approx 15 inch to 2 inch When the bottom spool shifted the injured employees finger was caught due to hand placement in the tight area below the support
Injury or illness
Tip of Left middle Finger
Object or substance involved
Piping Flanges
Summary line
Tip of Left middle Finger
Employee and industry
- Job description
- Boilermaker
- SOC code
- 9999 — Uncoded
- NAICS code
- 237990
- NAICS vintage
- 2012
- Avg employees
- 29
- Total hours worked
- 59649
- EIN
- 721513047
- Establishment ID
- 1001103
- Employer case #
- 69607
When (timing detail)
- Date of incident
- Shift started
- 7:00
- Time of incident
- 9:45
- Filing year
- 2024
- Submitted
- 25FEB2025:18:40:00
Source