2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Fort Benning Commissary GA

Injury · Other recordable case

On , an injury at Fort Benning Commissary GA in Jacksonville, FL 32209 resulted in other recordable case. Employee was project Manager in custodial services.

Establishment
Fort Benning Commissary GA
Parent company
The Right 2 Work Corporation (R2W)
Street
1010 N Davis Street, Suite 205
City
Jacksonville
State
FL
ZIP
32209
On-site location
Warehouse near baler #2
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

While replacing the baler wire he inadvertently touched an exposed wire on the adjacent generator.

While replacing the baler wire he inadvertently touched an exposed wire on the adjacent generator. This contact resulted in an electrical shock to his right hand. Subsequently his heart monitor ceased functioning and restarted automatically after ten minutes.

Electrical shock in right hand and heart moitor rebooted.

Exposed electrical wire

While replacing the baler wire he inadvertently touched an exposed wire on the adjacent generator. This contact resulted in an electrical shock to his right hand. His heart monitor ceased functioning and restarted automatically after 10 minutes.

Job description
Project Manager
SOC code
13-1082 — Project Management Specialists
NAICS code
561720 — Custodial services
NAICS vintage
2012
Avg employees
62005
Total hours worked
48
EIN
161779658
Establishment ID
435392
Employer case #
4
Date of incident
Shift started
20:00
Time of incident
4:15
Filing year
2024
Submitted
27FEB2025:21:16:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.