Cleveland, OH —
OSHA Injury Report: Plasman-Cleveland AB
Injury · Other recordable case
At a glance
On , an injury at Plasman-Cleveland AB in Cleveland, OH 44111 resulted in other recordable case. Employee was machine Operator in chrome plating metals and metal products for the trade.
Where did this happen?
- Establishment
- Plasman-Cleveland AB
- Parent company
- Plasman
- Street
- 3000 W. 121st St
- City
- Cleveland
- State
- OH
- ZIP
- 44111
- On-site location
- Hoist line Nitric Feed station
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Performing an equipment check walk through.
What happened
Employee making rounds noted nitric feed line from pump was leaking so she unplugged the pump. When unplugged the hose immediately back flowed and released nitric droplets through a split in the tubing contacting the employee on the chin and left front shoulder collarbone upper chest area.
Injury or illness
Chemical Burn 1st degree (Superficial) chin. (Note: left front shoulder collarbone upper chest area did not get burned she immediately took off her uniform shirt).
Object or substance involved
nitric acid droplets
Summary line
Chemical Burn 1st degree (Superficial) chin from nitric acid droplets
Employee and industry
- Job description
- Machine Operator
- SOC code
- 51-4199 — Metal Workers and Plastic Workers, All Other
- NAICS code
- 332813 — Chrome plating metals and metal products for the trade
- NAICS vintage
- 2022
- Avg employees
- 126
- Total hours worked
- 223605
- EIN
- 472516741
- Establishment ID
- 959285
- Employer case #
- 3
When (timing detail)
- Date of incident
- Shift started
- 15:00:00.000
- Time of incident
- 16:30:00.000
- Submitted
- 03JAN24:15:25:00
Source