2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Filtration : Colorado Springs EMAM

Injury · Days away from work

On , an injury at Filtration : Colorado Springs EMAM in Colorado Springs, CO 80907 resulted in days away from work. Employee was coop or intern in north American Industrial Classification.

Establishment
Filtration : Colorado Springs EMAM
Parent company
Baldwin Filters, Inc.
Street
1210 Garden of the Gods Road
City
Colorado Springs
State
CO
ZIP
80907
On-site location
Near final cure oven in in clip testing area
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
74
Days restricted or transferred
27

While working on a clipper machine a door that was in an elevated position became dislodged when an alternative guard door was opened. The initial guard door that was in the elevated position slammed shut striking the TMs left little finger

While working on a clipper machine a door that was in an elevated position became dislodged when an alternative guard door was opened. The initial guard door that was in the elevated position slammed shut striking the TMs left little finger

Crushing injury Finger Left Little Finger

Struck by falling machine guard

While working on a clipper machine a door that was in an elevated position became dislodged when an alternative guard door was opened. The initial guard door that was in the elevated position slammed shut striking the TMs left little finger

Job description
Coop or intern
SOC code
9999 — Uncoded
NAICS code
336390 — North American Industrial Classification
NAICS vintage
2022
Avg employees
51
Total hours worked
102443
EIN
340451060
Establishment ID
1009650
Employer case #
1
Date of incident
Shift started
7:00:00.000
Time of incident
7:00:00.000
Submitted
05FEB24:21:08:00