Warren, OH —
OSHA Injury Report: ClarkWestern Dietrich Building Systems - Warren, OH
Injury · Days away from work
At a glance
On , an injury at ClarkWestern Dietrich Building Systems - Warren, OH in Warren, OH 44483 resulted in days away from work. Employee was operator in studs, sheet metal (except stampings), manufacturing.
Where did this happen?
- Establishment
- ClarkWestern Dietrich Building Systems - Warren, OH
- Parent company
- ClarkWestern Dietrich Building Systems
- Street
- 1985 North River Rd. NE
- City
- Warren
- State
- OH
- ZIP
- 44483
- On-site location
- Amada Turret Press
What was the outcome?
- Outcome
- Days away from work (code 2)
- Type
- Injury (code 1)
- Days away from work
- 106
Before the incident
Employee was operating the Amada [REDACTED]. They walked in front of the entrance to the loading unloading station on their way to the loading unloading operator control panel.
What happened
As they were walking they stepped on a plastic chain that was laying on the floor (their foot slid on the chain causing them to lose their balance and fall to the ground).
Injury or illness
Sprains to the lower back and left foot ankle
Object or substance involved
Plastic chain
Summary line
Sprains to back L ankle foot EE was walking by press loading unload station when they stepped on a plastic chain lying on the floor causing them to lose their balance and fall to the ground.
Employee and industry
- Job description
- Operator
- SOC code
- 51-4199 — Metal Workers and Plastic Workers, All Other
- NAICS code
- 332322 — Studs, sheet metal (except stampings), manufacturing
- NAICS vintage
- 2022
- Avg employees
- 132
- Total hours worked
- 260598
- EIN
- 275010387
- Establishment ID
- 1243798
- Employer case #
- 25-04
When (timing detail)
- Date of incident
- Shift started
- 11:00
- Time of incident
- 22:30
- Filing year
- 2025
- Submitted
- 15JAN26:14:20:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2025. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.