2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: 4front Engineered Solutions

Injury · Job transfer or restriction

On , an injury at 4front Engineered Solutions in Carrollton, TX 75006 resulted in job transfer or restriction. Employee was welder in fabricated structural metal manufacturing.

Establishment
4front Engineered Solutions
Parent company
4front Engineered Solutions
Street
1612 Hutton Drive suite 140
City
Carrollton
State
TX
ZIP
75006
On-site location
Final Table (Assembly)
Outcome
Job transfer or restriction (code 3)
Type
Injury (code 1)
Days restricted or transferred
5

Welding components

Employee was welding onto a component without proper electrical continuity grounding simultaneously touching the ungrounded component with their hip closing the electrical loop and causing an electrical shock

Contusion to left hip Electric Shock

Welding Tool

Employee suffered an electric shock while welding onto a component without proper electrical continuity grounding

Job description
Welder
SOC code
51-4121 — Welders, Cutters, Solderers, and Brazers
NAICS code
332312 — Fabricated structural metal manufacturing
NAICS vintage
2012
Avg employees
363
Total hours worked
741004
EIN
390866333
Establishment ID
820378
Employer case #
4
Date of incident
Shift started
16:30
Time of incident
18:15
Filing year
2025
Submitted
16JAN26:21:18:00