Sumner, IA —
OSHA Injury Report: Life Line Emergency Vehicles
Injury · Days away from work
At a glance
On , an injury at Life Line Emergency Vehicles in Sumner, IA 50674 resulted in days away from work. Employee was assembler in ambulances assembling on purchased chassis.
Where did this happen?
- Establishment
- Life Line Emergency Vehicles
- Parent company
- Folience
- Street
- 1 Life Line Drive
- City
- Sumner
- State
- IA
- ZIP
- 50674
- On-site location
- Electrical Department-Zone 5
What was the outcome?
- Outcome
- Days away from work (code 2)
- Type
- Injury (code 1)
- Days away from work
- 4
- Days restricted or transferred
- 2
Before the incident
Normal work activities of installing AC systems into the modular of ambulances.
What happened
Employee stepped down onto a wooden step inside the inner stairwell of the ambulance and wooden step broke and employee fell out of the side of the ambulance hurting her ankle and puncturing her thigh with a piece of the broken wooden step.
Injury or illness
Injury-Puncture to back of right thigh and right ankle injury.
Object or substance involved
Piece of broken wooden step steps and concrete floor.
Summary line
Employee stepped down onto a wooden step inside the inner stairwell of the ambulance and wooden step broke and employee fell out of the side of the ambulance hurting her ankle and puncturing her thigh with a piece of the broken wooden step.
Employee and industry
- Job description
- Assembler
- SOC code
- 51-2099 — Assemblers and Fabricators, All Other
- NAICS code
- 336211 — Ambulances assembling on purchased chassis
- NAICS vintage
- 2012
- Avg employees
- 205
- Total hours worked
- 398209
- EIN
- 411528099
- Establishment ID
- 313689
- Employer case #
- 8
When (timing detail)
- Date of incident
- Shift started
- 6:00
- Time of incident
- 13:50
- Filing year
- 2025
- Submitted
- 26JAN26:22:08:00
Source