2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: LPC Crosswhite

Injury · Other recordable case

On , an injury at LPC Crosswhite in Portland, OR 97206 resulted in other recordable case. Employee was xray Operative in nonferrous die-casting foundries.

Establishment
LPC Crosswhite
Street
9169 SE 67th Ave
City
Portland
State
OR
ZIP
97206
On-site location
LSBS 3
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

On [REDACTED] a Radiologic Evaluator was inspecting part number 30905 using a read fixture. During the process the employee moved to the opposite side of the fixture to partially relieve the threaded screw braking device on the backside rollers. Upon returning to the inspection side the employee’s left middle finger was crushed between the roller and the flange of the part while rotating it. The employee was wearing the designated PPE for handling castings and performing a routine task. The incident was immediately reported to the shift lead and another employee provided first aid. The department supervisor and safety personnel contacted AMR and the employee was transported to the hospital for treatment. All 30905 fixtures were placed on Stop Work until improve guarding or handling methods are developed.

On [REDACTED] a Radiologic Evaluator was inspecting part number 30905 using a read fixture. During the process the employee moved to the opposite side of the fixture to partially relieve the threaded screw braking device on the backside rollers. Upon returning to the inspection side the employee’s left middle finger was crushed between the roller and the flange of the part while rotating it. The employee was wearing the designated PPE for handling castings and performing a routine task. The incident was immediately reported to the shift lead and another employee provided first aid. The department supervisor and safety personnel contacted AMR and the employee was transported to the hospital for treatment. All 30905 fixtures were placed on Stop Work until improve guarding or handling methods are developed.

Crushing injury Hand Left Middle Finger

Part number 30905 & read fixture

Crushing injury Hand Left Middle Finger Part number 30905 & read fixture. Caught in under on between

Job description
Xray Operative
SOC code
00-9900 — Insufficient Information - NIOSH
NAICS code
331523 — Nonferrous die-casting foundries
NAICS vintage
2022
Avg employees
250
Total hours worked
638414
Establishment ID
1447986
Employer case #
211
Date of incident
Shift started
6:00
Time of incident
8:50
Filing year
2025
Submitted
29JAN26:18:57:00