Orwigsburg, PA —
OSHA Injury Report: Shalmet
Injury · Other recordable case
At a glance
On , an injury at Shalmet in Orwigsburg, PA 17961 resulted in other recordable case. Employee was operator in polishing metals and metal products for the trade.
Where did this happen?
- Establishment
- Shalmet
- Parent company
- Carpenter Technology
- Street
- 116 Pinedale Industrial Road
- City
- Orwigsburg
- State
- PA
- ZIP
- 17961
- On-site location
- Large Leblond Lathe located in A-bay Shalmet Orwigsburg.
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Please see answer to Question 15 below for details.
What happened
The employee was operating the [REDACTED] (Large Leblond[REDACTED] lathe. The employee was processing W81135 [REDACTED] 915 order which has a start size of 7.125 and was turning the bar down to 6.875 The removal was .350. The employe was 16 into the turning process when the chips form the bar being processed were coming out in a stringer form. The employee used a hand safe tool in an attempt to remove the stringer while the bar was being processed. The stringer broke free resulting in a laceration of the right forearm.
Injury or illness
Laceration Cut Open Wound Arm Forearm
Object or substance involved
Laceration Cut Open Wound Arm Forearm
Summary line
Laceration Cut Open Wound Arm Forearm Sharp Metal Chips Contact with sharp object
Employee and industry
- Job description
- Operator
- SOC code
- 51-4199 — Metal Workers and Plastic Workers, All Other
- NAICS code
- 332813 — Polishing metals and metal products for the trade
- NAICS vintage
- 2022
- Avg employees
- 100
- Total hours worked
- 200496
- Establishment ID
- 1313053
- Employer case #
- 71
When (timing detail)
- Date of incident
- Shift started
- 22:00
- Time of incident
- 3:00
- Filing year
- 2025
- Submitted
- 05FEB26:14:38:00
Source