Fridley, MN —
OSHA Injury Report: US, MN Fridley, Cummins Power Systems
Injury · Days away from work
At a glance
On , an injury at US, MN Fridley, Cummins Power Systems in Fridley, MN 55432 resulted in days away from work. Employee was assembler III in motor generator sets (except automotive, turbine generator sets) manufacturing.
Where did this happen?
- Establishment
- US, MN Fridley, Cummins Power Systems
- Parent company
- Cummins Inc
- Street
- 1400 73rd Avenue NE
- City
- Fridley
- State
- MN
- ZIP
- 55432
- On-site location
- Systems
What was the outcome?
- Outcome
- Days away from work (code 2)
- Type
- Injury (code 1)
- Days away from work
- 49
Before the incident
Trying to put a panel in a DMC unit without a lift plan.
What happened
When injured employee was trying to lift the bottom to put the panel in place they felt a pop in their forearm. They thought it would get better but it did not. They then reported it to the onsite health center on [REDACTED]. An MRI was ordered and first available date was [REDACTED] (due to needing special machine due to employee 's physical stature). [REDACTED] 8 MRI determined distal bicep tendon full thickness tear with retraction of the tendon.
Injury or illness
distal bicep tendon full thickness tear with retraction of the tendon. Employee was referred to orthopedics who recommended surgery. Surgery was completed 5 17 23
Object or substance involved
panel
Summary line
Distal bicep tendon full thickness tear with retraction of the tendon received surgery to correct
Employee and industry
- Job description
- Assembler III
- SOC code
- 51-2022 — Electrical and Electronic Equipment Assemblers
- NAICS code
- 335312 — Motor generator sets (except automotive, turbine generator sets) manufacturing
- NAICS vintage
- 2022
- Avg employees
- 1465
- Total hours worked
- 2015020
- EIN
- 410965373
- Establishment ID
- 932896
- Employer case #
- 11
When (timing detail)
- Date of incident
- Shift started
- 7:00:00.000
- Time of incident
- 10:30:00.000
- Submitted
- 07FEB24:21:38:00
Source