Grand Rapids, MI —
OSHA Injury Report: Hutchinson Antivibration (Grand Rapids)
Injury · Job transfer or restriction
At a glance
On , an injury at Hutchinson Antivibration (Grand Rapids) in Grand Rapids, MI 49503 resulted in job transfer or restriction. Employee was engineer in mechanical rubber goods (i.e., extruded, lathe-cut, molded) manufacturing.
Where did this happen?
- Establishment
- Hutchinson Antivibration (Grand Rapids)
- Parent company
- Hutchinson Antivibration - Grand Rapids
- Street
- 460 Fuller Avenue NE
- City
- Grand Rapids
- State
- MI
- ZIP
- 49503
- On-site location
- Validation Lab
What was the outcome?
- Outcome
- Job transfer or restriction (code 3)
- Type
- Injury (code 1)
- Days restricted or transferred
- 10
Before the incident
A hydraulic pump had stopped working due to low oil sensor being tripped. An employee noticed the alarm and added oil to the pump bringing it back up to level. After filling the employee pressed the start button.
What happened
Pressing the start button resulted in a small explosion in the pump’s electrical panel. The panel door swung open hitting the employee in the shoulder and elbow.
Injury or illness
Laceration of the elbow.
Object or substance involved
The digital flow meter on the panel door.
Summary line
Laceration to elbow by electrical panel door.
Employee and industry
- Job description
- Engineer
- SOC code
- 17-2112 — Industrial Engineers
- NAICS code
- 326291 — Mechanical rubber goods (i.e., extruded, lathe-cut, molded) manufacturing
- NAICS vintage
- 2022
- Avg employees
- 370
- Total hours worked
- 588574
- EIN
- 382708017
- Establishment ID
- 1417560
- Employer case #
- 25-1
When (timing detail)
- Date of incident
- Shift started
- 7:00
- Time of incident
- 8:00
- Filing year
- 2025
- Submitted
- 12FEB26:15:20:00
Source