Fitchburg, MA —
OSHA Injury Report: Micron Products
Injury · Other recordable case
At a glance
On , an injury at Micron Products in Fitchburg, MA 1420 resulted in other recordable case. Employee was maintenance Technician in balloons, plastics, manufacturing.
Where did this happen?
- Establishment
- Micron Products
- Parent company
- Micron Products
- Street
- 25 Sawyer Passway
- City
- Fitchburg
- State
- MA
- ZIP
- 1420
- On-site location
- 41 Sawyer Passway - MRB Area
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Worker was drilling core samples of the concrete floor near [REDACTED] area to the right of the ramp from the lower molding floor to the upper molding floor.
What happened
Worker was using a base mounted concrete drill to extract samples from the floor. The goal was to determine the concretes thickness and confirm structural stability for possible CNC equipment installation. During drilling the bit caught on material later identified as embedded steel mesh within the concrete.
Injury or illness
The drill spun the base unit around and the base unit struck Worker in the back of left ankle just above foot.
Object or substance involved
Stand Mounted Concrete Core Drill rented from [REDACTED] 's Rental in Leominster.
Summary line
Drill spun around base unit and base unit struck EE in back of left ankle just above foot
Employee and industry
- Job description
- Maintenance Technician
- SOC code
- 49-9041 — Industrial Machinery Mechanics
- NAICS code
- 326199 — Balloons, plastics, manufacturing
- NAICS vintage
- 2012
- Avg employees
- 90
- Total hours worked
- 164831
- EIN
- 042501572
- Establishment ID
- 912182
- Employer case #
- 19154
When (timing detail)
- Date of incident
- Shift started
- 6:55
- Time of incident
- 11:00
- Filing year
- 2025
- Submitted
- 19FEB26:18:23:00
Source