Kansas City, MO —
OSHA Injury Report: Custom Truck One Source - Kansas City
Injury · Job transfer or restriction
At a glance
On , an injury at Custom Truck One Source - Kansas City in Kansas City, MO 64152 resulted in job transfer or restriction. Employee was gEAR SHOP MANAGER in cranes, construction-type, manufacturing.
Where did this happen?
- Establishment
- Custom Truck One Source - Kansas City
- Parent company
- Custom Truck One Source
- Street
- 7701 Independence Ace
- City
- Kansas City
- State
- MO
- ZIP
- 64152
- On-site location
- Bld A Gear Shop
What was the outcome?
- Outcome
- Job transfer or restriction (code 3)
- Type
- Injury (code 1)
- Days restricted or transferred
- 3
Before the incident
Using brake press
What happened
Employee was using the brake press on a PTO when the yoke came loose and struck the employee in the RT hand causing lacerations on RT index finger middle finger and thumb. Employee was treated with first aid and sent to the clinic for further treatment.
Injury or illness
Laceration of Hand Right Side
Object or substance involved
Tools Instruments and Equipment - Tools instruments and equipment unspecified
Summary line
Employee was using the brake press on a PTO when the yoke came loose and struck the employee in the RT hand causing lacerations on RT index finger middle finger and thumb. Employee was treated with first aid and sent to the clinic for further treatment.
Employee and industry
- Job description
- GEAR SHOP MANAGER
- SOC code
- 2666211 — Managers, All Other
- NAICS code
- 333120 — Cranes, construction-type, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 1060
- Total hours worked
- 1476474
- EIN
- 811853358
- Establishment ID
- 1312685
- Employer case #
- FY25-0013
When (timing detail)
- Date of incident
- Shift started
- 6:00
- Time of incident
- 12:40
- Filing year
- 2025
- Submitted
- 01MAR26:13:40:00
Source