2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Hartung Glass Renton

Injury · Job transfer or restriction

On , an injury at Hartung Glass Renton in Renton, WA 98057 resulted in job transfer or restriction. Employee was turnover offloader in insulating glass, sealed units, made in glass making plants.

Establishment
Hartung Glass Renton
Parent company
Hartung Glas Industries
Street
3351 East Valley Road
City
Renton
State
WA
ZIP
98057
On-site location
Breakout table
Outcome
Job transfer or restriction (code 3)
Type
Injury (code 1)
Days restricted or transferred
10

Employee was standing at the end of the cutting table holding a sheet of glass

A sensor on the machine was dirty and failed sending a second glass sheet through unexpectedly striking the worker

Shoulder strain

Glass sheet

Shoulder strain from being struck by glass sheet

Job description
Turnover offloader
SOC code
53-7062 — Laborers and Freight, Stock, and Material Movers, Hand
NAICS code
327211 — Insulating glass, sealed units, made in glass making plants
NAICS vintage
2022
Avg employees
100
Total hours worked
215396
EIN
371480947
Establishment ID
418099
Employer case #
1
Date of incident
Shift started
19:00:00.000
Time of incident
23:30:00.000
Submitted
16JAN24:22:57:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.