2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: ISCO Industries, Inc - Houston

Injury · Other recordable case

On , an injury at ISCO Industries, Inc - Houston in Houston, TX 77048 resulted in other recordable case. Employee was fabricator in chemical toilets, plastics, manufacturing.

Establishment
ISCO Industries, Inc - Houston
Parent company
ISCO Industries, Inc
Street
5610 Almeda Genoa Road
City
Houston
State
TX
ZIP
77048
On-site location
Fabrication area
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

Working on 618 fusion machine.

Worker wanted to face one side of the [REDACTED] pipe and used a plastic flange protector to put between the pipe and facer and attempted to bring the right side of the pipe in closer due to the flange protector being smaller than the pipe. When he moved the hydraulic switch he was under the impression he would be able to move his fingers in time. The right side of the pipe and facer crushed his left middle and index finger.

Complete traumatic transphalangeal amputation and crushing injury of left middle finger; Complete traumatic transphalangeal amputation and crushing injury of left index finger.

McElroy 618 Fusion Machine.

Fingertip amputation

Job description
Fabricator
SOC code
51-2099 — Assemblers and Fabricators, All Other
NAICS code
326191 — Chemical toilets, plastics, manufacturing
NAICS vintage
2022
Avg employees
36
Total hours worked
97344
Establishment ID
958909
Employer case #
1
Date of incident
Shift started
7:30:00.000
Time of incident
10:00:00.000
Submitted
20FEB24:15:34:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.