SAN ANTONIO, TX —
OSHA Injury Report: Improved Piping Products, Inc.
Injury · Job transfer or restriction
At a glance
On , an injury at Improved Piping Products, Inc. in SAN ANTONIO, TX 78218 resulted in job transfer or restriction. Employee was quality control in fittings and unions, rigid plastics pipe, manufacturing.
Where did this happen?
- Establishment
- Improved Piping Products, Inc.
- Parent company
- IMPROVED PIPING PRODUCTS
- Street
- 5010 Space Center Drive
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78218
- On-site location
- QC warehouse quality area.
What was the outcome?
- Outcome
- Job transfer or restriction (code 3)
- Type
- Injury (code 1)
- Days restricted or transferred
- 107
Before the incident
Torquing bolts of a pressure test assembly.
What happened
While pulling on a wrench employee strained his left arm around the bicep and upper forearm area.
Injury or illness
Strain to the left bicep.
Object or substance involved
Physical pulling motion.
Summary line
While tightening bolts on a ring employee felt a pain in his left bicep.
Employee and industry
- Job description
- Quality control
- SOC code
- 51-9061 — Inspectors, Testers, Sorters, Samplers, and Weighers
- NAICS code
- 326122 — Fittings and unions, rigid plastics pipe, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 100
- Total hours worked
- 189849
- EIN
- 942593029
- Establishment ID
- 1070566
- Employer case #
- 3
When (timing detail)
- Date of incident
- Shift started
- 5:30:00.000
- Time of incident
- 9:00:00.000
- Submitted
- 19JAN24:14:27:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.