2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Koax Corp

Injury · Days away from work

On , an injury at Koax Corp in Oklahoma City, OK 73106 resulted in days away from work. Employee was assembler in heat exchangers manufacturing.

Establishment
Koax Corp
Parent company
Koax Corp
Street
510 N Indiana Ave
City
Oklahoma City
State
OK
ZIP
73106
On-site location
Pedrick Coiler
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
84
Days restricted or transferred
170

The employee was making “W” coils on the Pedrick Coiler when he noticed an alignment issue causing an unwanted bend in the coil. This prompted the [REDACTED] to re-align the coiler clamp and die assembly.

The employee was using a set-up bar placed between the coiler clamp and die assembly when he placed his right fingers between the coiler clamp and the die while checking the alignment adjustment he had made. The clamp inadvertently closed pinching his right-hand ring and middle fingers between the clamp and the die.

Open fracture of the right-hand ring and middle fingers. Once at the emergency room the tips of the right-hand ring and middle fingers were removed just before the first knuckle.

Coiler clamp and die assembly

Open Fracture and amputation of right middle and ring fingers from coiler clamp pinching fingers

Job description
Assembler
SOC code
51-2099 — Assemblers and Fabricators, All Other
NAICS code
332410 — Heat exchangers manufacturing
NAICS vintage
2022
Avg employees
43
Total hours worked
93053
EIN
731284158
Establishment ID
912719
Employer case #
23-Jan
Date of incident
Shift started
5:00:00.000
Time of incident
5:42:00.000
Submitted
26JAN24:18:08:00