HUDSON, WI —
OSHA Inspection: WEST INDUSTRIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WEST INDUSTRIES, INC. in 1700 LIVINGSTONE ROAD, HUDSON, WI 54016 (NAICS 000000). OSHA activity number 101670198.
Where did this inspection happen?
- Establishment
- WEST INDUSTRIES, INC.
- Site address
- 1700 LIVINGSTONE ROAD
- City
- HUDSON
- State
- WI
- ZIP
- 54016
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3599
- Employees
- 68
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
11 citations on file for this inspection.
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $420.00 · Current $420.00
1910.212 A01
- Issued
- Abate by
1904.2 A
- Issued
- Abate by
- Penalty
- Initial $140.00 · Current $75.00 Reduced
Recent events (2)
- — I (R) $75.00
- — Z (R) $140.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $560.00 · Current $280.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The Employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Employer did not establish a written lockout/tagout program for electrical work conducted frequently in plant on 7/19/88. Hazard of possible exposure to electrical energy resulting in electrical shock/ electrocution. Among other methods, one feasible and acceptable abatement method to correct this hazard is to establish and enforce an adequate plant lockout/tagout procedure such as that stipulated by NFPA 70E - 1983, National Fire Protection Association Standard for Electrical Safety Requirements for Employee Workplaces. Essential elements of the lockout/tagout procedure would include: 1) Develop safe work practices for de-energizing circuits and equipment to prevent electric shock or other injuries resulting from direct or indirect electrical contacts when the work is performed near or on equipment circuits which are or may be energized. These practices shall be consistent with the nature and extent of the associated electrical hazards and developed before the circuits and equipment are de-energized (1910.333)(a) & 333(b)(1)(A)(i). 2) De-energize live parts to which an employee may be exposed before the employee works on or near them, unless it can be demonstrated that de-energizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. In such cases, the procedures outlined in item 9 for working on energized equipment shall be followed (1910.333)(a)(1). 3) Disconnect all electric sources from circuits and equipment upon which work is to be performed. Control circuit devices, such as push buttons, selector switches and interlocks, may not be used as the safe means for de-energizing circuits or equipment. Interlocks for electric equipment may not be used as a substitute for lockout and tagging procedures (1910.333)(b)(2)(i)(B). 4) Release stored electrical energy in circuits and equipment which might endanger personnel. Capacitors shall be discharged and high capacitance elements shall be short-circuited and grounded (1910.333) (b)(2)(i)(C). 5) Place a lock and a tag on each disconnecting means used to deenergize circuits and equipment on which work is to be performed. The lock shall be attached so as to prevent persons from operating the disconnecting means unless they resort to undue force or use of tools. The tag shall contain a statement prohibiting unauthorized operations of the disconnecting means and removal of the tag (1910. 333)(b)(1)(2)(A). 6) If a lock cannot be applied, a tag may be used without a lock provided the following additional requirements are met: i) Tags are of a distinctive, employer-standardized, design that clearly prohibits unauthorized energizing of circuits and removal of the tag. ii) Additional safety measures, such as removal of isolating circuit elements, blocking of controlling switches or opening extra disconnecting devices, are employed. iii) Only on circuit or piece of equipment is de-energized. iv) The tagout period does not extend beyond the work shift. v) All persons who have access to controlling devices are trained and familiar with the employer's tagging procedures (1910.333)(b)(2)(ii) (C) & (D). 7) A qualified person, see 29 CFR 1910.399(a)(100), shall operate the equipment operating controls or otherwise verify that the equipment cannot be restarted. The qualified person shall use test equipment to test circuit elements and electrical parts to which employees will be exposed and shall verify that the circuit elements and equipment parts are de-energized before work is allowed to proceed. The test shall also determine if any energized condition exists as a result of inadvertently induced voltage or unrelated voltage backfeed even through specific parts of the circuit have been de-energized and presumed to be safe (1910.333)(b)(2)(iii). 8) Before circuits or equipment are re-energized, even temporarily, a qualified person shall conduct tests and visual inspections, as necessary, to vertify all tools, electrical jumpers, shorts, grounds and other such devices have been removed so that the circuits and equipment can be safety energized. A visual determination shall be made to assure all employees are clear of circuits and equipments before they are energized (1910.333(b)-(2)(iv). 9) Only qualified persons may work on electric circuit parts or equipment that have not been de-energized in accordance with items 1 through 8 above. Such persons shall be capable of working safely on energized circuits and shall be familiar with proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulating tools. Safety related work practices shall be developed which are suitable to the work being performed and for the voltage level of the exposed electric conductor or circuit parts (1910.333)(a)(2) and (c). 10) Employees who may reasonably be expected to face a risk of injury due to electric shock or other electrical hazards shall be trained in and familiar with the safety-related work practices outlined in items 1 through 7 above that pertain to their respective job assignments. Furthermore, qualified persons (i.e. those permitted to work on or near exposed energized parts) shall, in addition to the above training requirements, also be trained in and familiar with the following: i) The skills and techniques necessary to distinguish exposed live parts from other parts of electric equipment. ii) The skills and techniques necessary to determine the nominal voltage of exposed live parts. iii) Safety-related work practices used to protect employees against contact with energized circuit parts directly with any part of their body or indirectly through other conductive objects (1910.332)(b) (1)(3).
Recent events (2)
- — I (S) $280.00
- — Z (S) $560.00
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $420.00 · Current $420.00
Recent events (2)
- — I (S) $420.00
- — Z (S) $420.00
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $700.00 · Current $700.00
Recent events (2)
- — I (R) $700.00
- — Z (R) $700.00
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $140.00 · Current $140.00
1903.2 A01
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 F04 II
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 G01
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 H
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
More inspections at WEST INDUSTRIES, INC.
HUDSON, WI—2000-08-16 00:00:00
WEST INDUSTRIES, INC.
HUDSON, WI—1999-10-12 00:00:00
WEST INDUSTRIES, INC.
HUDSON, WI—1991-03-27 00:00:00
WEST INDUSTRIES, INC.
HUDSON, WI—1991-01-23 00:00:00
WEST INDUSTRIES, INC.
HUDSON, WI—1990-11-21 00:00:00
WEST INDUSTRIES, INC.
View WEST INDUSTRIES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC