Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DYCO ELECTRONICS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DYCO ELECTRONICS INC. in 35 SOUTH MAIN STREET, ANGOLA, NY 14006 (NAICS 000000). OSHA activity number 106913569.

Watch Dyco Electronics INC. — free Get an email when a new federal OSHA severe-injury report for Dyco Electronics INC. is published. One employer, no account, unsubscribe in one click.
Site address
35 SOUTH MAIN STREET
City
ANGOLA
State
NY
ZIP
14006
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3612
Employees
20
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 07 4 instances 3 exposed
Issued
Abate by
Penalty
Initial $560.00 · Current $560.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that:
a) Employees were exposed to the hazard of fire and or explosion while
baking varnish coated transformers in three ovens and one Blue
Electric Co. oven which were not approved for flammable solvents.
Employees could suffer severe burns, fractures and death should a
fire and or explosion result.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to: a) install a preventilation purge cycle, b)
install an exhaust ventilation safety switch, c) make a determination of
safety ventilation requirements, and d) implement a regular maintenance
program to clean and remove combustible residues from the oven interior
as stipulated by NFPA 86A-1981, standard for ovens and furnaces, in
sections 5-2.1, 5-3.1, 4-1.1, and 7-3.

1910.305 G01 III

Serious Gravity 05 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $300.00 · Current $300.00

1910.303 F

Other-than-serious Gravity 00 2 instances 25 exposed
Issued
Abate by

1910.304 F04

Other-than-serious Gravity 00 2 instances 3 exposed
Issued
Abate by

1910.305 B01

Other-than-serious Gravity 00 1 instance 1 exposed
Issued
Abate by

1910.305 B02

Other-than-serious Gravity 00 1 instance 1 exposed
Issued
Abate by

1910.305 G02 III

Other-than-serious Gravity 00 1 instance 2 exposed
Issued
Abate by

View DYCO ELECTRONICS INC.'s full OSHA safety record →