RAPID CITY, SD —
OSHA Inspection: MERILLAT INDUSTRIES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MERILLAT INDUSTRIES, LLC in 4300 HWY 79 SOUTH, RAPID CITY, SD 57701 (NAICS 000000). OSHA activity number 107118499.
Where did this inspection happen?
- Establishment
- MERILLAT INDUSTRIES, LLC
- Site address
- 4300 HWY 79 SOUTH
- City
- RAPID CITY
- State
- SD
- ZIP
- 57701
- Mailing
- BOX 4040, RAPID CITY, SD 57709
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2493
- Employees
- 334
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
1910.37 K02
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1750.00 Reduced
Recent events (2)
- — I (S) $1750.00
- — Z (S) $3500.00
1910.219 C04 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1750.00 Reduced
Recent events (2)
- — I (S) $1750.00
- — Z (S) $3500.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $35000.00 · Current $35000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) On or about November 18, 1992, and at times prior to that date, employees engaged in operations in and around the Sanding Department were exposed to the hazard of severe burns and other serious injuries caused by a wood dust explosion propagating back through the dust extraction system. Among other methods, one feasible and acceptable abatement method to correct this hazard is to: 1. Increase the extraction capacity of the pneumatic dust collection system to conform with the sanding equipment manufacturer's design recommendations. 2. Install explosion venting or explosion suppression devices in the dust collection equipment as specified in NFPA Code 664.
Recent events (2)
- — I (W) $35000.00
- — Z (W) $35000.00
More inspections at MERILLAT INDUSTRIES, LLC
RAPID CITY, SD—2005-12-13 00:00:00
MERILLAT INDUSTRIES, LLC
RAPID CITY, SD—2002-12-18 00:00:00
MERILLAT INDUSTRIES, LLC
RAPID CITY, SD—1988-02-23 00:00:00
MERILLAT INDUSTRIES, LLC
View MERILLAT INDUSTRIES, LLC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in SD
CLEAR LAKE, SD—2026-07-15
AEROTEK
YANKTON, SD—2026-07-14