OSHA Inspection: DFH ENVIRONMENTAL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DFH ENVIRONMENTAL in EAST ORANGE VA HOSPITAL, CENTER ST., EAST ORANGE, NJ 07079 (NAICS 000000). OSHA activity number 108663428.

Watch DFH Environmental — free Get an email when a new federal OSHA severe-injury report for DFH Environmental is published. One employer, no account, unsubscribe in one click.
Establishment
DFH ENVIRONMENTAL
Site address
EAST ORANGE VA HOSPITAL, CENTER ST.
City
EAST ORANGE
State
NJ
ZIP
07079
Mailing
BOX 985 NORTH SALEM ST., DOVER, NJ 07801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1799
Employees
8
Ownership type
A
Industry flags
Construction safety.

4 citations on file for this inspection.

1910.134 B07

Serious Gravity 03 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $500.00 · Current $500.00

1910.146 G02 I

Serious Gravity 03 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $500.00 · Current $500.00

5(a)(1)

Serious Gravity 03 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $750.00 · Current $750.00
Section 5(a)(1):  The employer did not furnish employment and a place of
employment which
were free from recognized hazards that were causing or likely to cause
death or serious
physical harm to employees in that employees were exposed to the hazard of
crushed or
broken bones from the unsafe operation of a pipe threader:
a)Building #8, boiler house
Employees exposed to the hazard of being caught in a pipe threader, were
operating a
Rigid 300 electric pipe threader, S/N 7592826, which was not provided with
an
operable foot switch control as required by the American National
Standards Institute
B208.1-1982 Section 4.4.
One feasible method of abatement would be to provide a momentary contact
device to
control power input to the pipe threading machine.  A guarded foot switch
is an
example of such a momentary contact device.
Violation observed on or about 6/8/95.

1910.146 D14

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Abate by

KGC, INC.

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 108663428.