ERIE, PA —
OSHA Inspection: X-CEL SERVICES, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of X-CEL SERVICES, INC. in 104 EAST 2ND STREET, ERIE, PA 16514 (NAICS 000000). OSHA activity number 113335459.
Where did this inspection happen?
- Establishment
- X-CEL SERVICES, INC.
- Site address
- 104 EAST 2ND STREET
- City
- ERIE
- State
- PA
- ZIP
- 16514
- Mailing
- P.O. BOX 37, 12 JACKSON STREET, MAYVILLE, NY 14757
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7349
- Employees
- 5
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1700.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)North Side of Building, Hamot Medical Center - Employee(s) engaged in window cleaning activities were exposed to fall hazards up to 80 feet. The following industry recognized practices were not in place on or about October 21, 1994: 1.Employee(s) were not adequately trained in the proper/safe use of all equipment provided them nor did the employer adequately supervise the use of the equipment to insure that the safe working practices were observed according to the ASME/ANSI A-39.1-1987, Safety Requirements for Window Cleaning. 2.The "A" frame apparatus (mule) that supported the boatswain chair was not securely anchored to the roof. 3.An employee was not using an independent fall arrest system that was properly secured to the structure. Among other methods, one feasible and acceptable method to correct this hazard is to: a.Implement a safety training program meeting ASME/ANSI A-39.1-1987, Safety Requirements for Window Cleaning that includes at least the following: 1.Training of employees in the use of the equipment before is used; 2.Inspection of equipment each day before use; 3.Proper rigging, including sound anchorages and tiebacks, in all cases, with particular emphasis on providing tiebacks when counterweights, cornice hooks, or similar non-permanent anchorage systems are used; 4.Use of a separate fall arrest system (including bodybelt, sit harness, or full body harness; rope grab or similar device; lifeline; and anchorage (all of which are completely independent of the friction device and it's support system)), so that any failure in a friction device, support seat (or harness), support line, or anchorage system will not affect the ability of the fall arrest system to operate and quickly stop the employee's fall; 5.All lines installed (such as by using knots, swages or eye splices) when rigging descent control devices shall be capable of sustaining a minimum tensile load of 5,000 pounds; 6.Provisions are made for rescue; 7.Ropes are effectively padded where they contact edges of the building, anchorage, obstructions, or other surfaces which might cut or weaken the rope; 8.Provisions are made for intermittent stabilization for descent in excess of 130 feet.
Recent events (2)
- — P (S) $1700.00
- — Z (S) $1700.00
1910.28 J04
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1700.00
Recent events (2)
- — P (S) $1700.00
- — Z (S) $1700.00
1910.20 G01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
Recent events (2)
- — P (S) $1600.00
- — Z (S) $1600.00
1910.20 G01
- Issued
- Abate by
Recent events (2)
- — P (O)
- — Z (O)
1910.20 G02
- Issued
- Abate by
Recent events (2)
- — P (O)
- — Z (O)
1910.1030 C01 I
- Issued
- Abate by
Recent events (2)
- — P (O)
- — Z (O)
1910.1200 E01
- Issued
- Abate by
Recent events (2)
- — P (O)
- — Z (O)
1910.1200 H
- Issued
- Abate by
Recent events (2)
- — P (O)
- — Z (O)
More inspections at X-CEL SERVICES, INC.
ERIE, PA—1996-05-22 00:00:00
X-CEL SERVICES, INC.
View X-CEL SERVICES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 113335459.