ST. LOUIS, MO —
OSHA Inspection: MASONIC TEMPLE
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MASONIC TEMPLE in 3681 LINDELL, ST. LOUIS, MO 63108 (NAICS 000000). OSHA activity number 113891253.
Where did this inspection happen?
- Establishment
- MASONIC TEMPLE
- Site address
- 3681 LINDELL
- City
- ST. LOUIS
- State
- MO
- ZIP
- 63108
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8641
- Employees
- 1
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $750.00 · Current $750.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: (a) Three employees were exposed and one suffered a fatal injury as a result of bypassing a mechanical safety lock that was intended to keep out unauthorized persons. (b) Employees who were expected to bypass the safety device had not received training in safe procedures, such as: 1)Checking to assure location of elevator. 2)Safe operation of the emergency device key and procedure to open the elevator door. 3)Awareness training for the fall hazard. (c)The emergency device was available to persons other than maintenance or authorized persons. While ultimate responsibility for correcting the hazard rests with the employer, given his/her superior knowledge of the work place, feasible and acceptable methods to correct this hazard, among others, are: (1)The qualified person(s) to use the emergency device to open the doors should be trained by a recognized elevator service company or trained in accordance with ANSI Standards and City elevator inspection procedures. The established procedure should be written. (2)In the absence of a qualified person to open the doors, the elevator service company should be summoned. Reference materials: American National Standard Safety Code for Elevators Dumbwaiters Escalators and Moving Walks; (ANSI A17.1-1971); Rule 111.9e and Rule 111.10.
Recent events (2)
- — I (S) $750.00
- — Z (S) $750.00
More inspections at MASONIC TEMPLE
Philadelphia, PA—1983-08-09 00:00:00
MASONIC TEMPLE
View MASONIC TEMPLE's full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in MO
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 113891253.