RAHWAY, NJ —
OSHA Inspection: O.S.H.A., INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of O.S.H.A., INC. in 276 HAMILTON ST., RAHWAY, NJ 07065 (NAICS 000000). OSHA activity number 113894075.
Where did this inspection happen?
- Establishment
- O.S.H.A., INC.
- Site address
- 276 HAMILTON ST.
- City
- RAHWAY
- State
- NJ
- ZIP
- 07065
- Mailing
- 276 HAMILTON ST., RAHWAY, NJ 07065
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7211
- Employees
- 130
- Ownership type
- A
Citations
22 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: On or about July 11, 1996, the employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employee(s) were exposed to operating freight elevator(s) and working in the vicinity of freight elevator(s) were exposed to the hazard of falling into the elevator shaft and/or being crushed by the elevator cab: a- Freight Elevator #1, near Ironers: Elevator shaftway on ground floor was completely open on one side, and the sliding gate interlock was defeated on the other side. The interlock device for the double doors on the second floor was also nonfunctional. b- Freight Elevator #2, Gown Dept: Sliding gate interlock on ground floor was defeated and the shaftway opening on the second floor was completely open. The collapsible gate could not be pulled completely across the opening on several attempts. Conditions noted on or about 7/11/96. Among other methods one feasible and acceptable abatement method to correct this hazard is to: 1- Equip each hoistway door with a hoistway door interlock device. 2) The interlock device shall hold the door in the locked position by means of gravity or by a restrained compression spring, or by both, or by means of a positive linkage. 3) The interlock shall lock the door in the closed position before the elevator can be operated. Reference Publication: 1- American National Standard Institute/American Society of Mechanical Engineers, A17.3 - 1986 - "Safety Code for Existing Elevators and Escalators". 2- BOCA - Basic Building Code - Article 26.icle
Recent events (4)
- — I $4700.00
- — Z $13500.00
- — P (S) $5000.00
1910.23 B01 I
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $2500.00
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3500.00
1910.23 D01 II
- Issued
- Abate by
1910.37 G02
- Issued
- Abate by
1910.37 K02
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3500.00
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3500.00
1910.157 D01
- Issued
- Abate by
1910.157 G01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3500.00
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
Recent events (2)
- — P (S) $5000.00
- — Z (S) $5000.00
1910.264 C04 IIIA
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $1500.00
1910.1030 D03 IX
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $2500.00
8400
1910.1030 F02 I
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $2500.00
8400
1910.1030 G02 IIA
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $2500.00
8400
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $55000.00 · Current $55000.00
1910.147 C02 III
- Issued
- Abate by
1910.264 D02 IA
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
Recent events (4)
- — I $4700.00
- — Z $13500.00
- — P (R) $5000.00
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $4000.00
1910.132 D01
- Issued
- Abate by
1910.212 A02
- Issued
- Abate by
1910.219 E03 I
- Issued
- Abate by
1910.1200 E01
- Issued
- Abate by
More inspections at O.S.H.A., INC.
RAHWAY, NJ—1998-04-27 00:00:00
O.S.H.A., INC.
RAHWAY, NJ—1997-06-23 00:00:00
O.S.H.A., INC.
RAHWAY, NJ—1997-04-15 00:00:00
O.S.H.A., INC.
RAHWAY, NJ—1997-03-11 00:00:00
O.S.H.A., INC.
RAHWAY, NJ—1995-09-22 00:00:00
O.S.H.A., INC.
View O.S.H.A., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 113894075.