FAJARDO, PR —
OSHA Inspection: DS OFIC SALUD AMBIENTAL FAJARDO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DS OFIC SALUD AMBIENTAL FAJARDO in HOSPITAL SAN PABLO, AVE. GENERAL VALERO, FAJARDO, PR 00738 (NAICS 000000). OSHA activity number 126951409.
Where did this inspection happen?
- Establishment
- DS OFIC SALUD AMBIENTAL FAJARDO
- Site address
- HOSPITAL SAN PABLO, AVE. GENERAL VALERO
- City
- FAJARDO
- State
- PR
- ZIP
- 00738
- Mailing
- P.O. BOX 70184, SAN JUAN, PR 00936
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8062
- Employees
- 14
- Ownership type
- C
Citations
5 citations on file for this inspection.
6A0001
- Issued
- Abate by
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: At the establishment: It were observed five (5) instances in which fissured sections on the ceiling structure in the second level of the building where Fajardo's Regional Ambiental Health Office is located, which posed the hazard of traumas and fractures, from slippings and falls on rainy days: a. At the office of the regional director secretary; b. At the collector's office; c. At the inspector's offices (men/women); d. At the secretaries office and, e. At the walkway. Among other methods, one feasible and acceptable abatement method to correct this hazard is to restore anew the ceiling with concrete and sealing compound. En el establecimiento: Se observaron cinco (5) casos en los cuales secciones resquebradas en la estructura del techo en el segundo nivel del edificio donde se ubica la Oficina Regional de Salud Ambiental de Fajardo los cuales constituyeron un riesgo de traumas y fracturas, por resbalones y caidas en dias lluviosos: a. En la oficina de la secretaria del director regional; b. En la oficina de la recaudadora; c. En las oficinas de los inspectores (hombres/mujeres); d. En la oficina de las secretarias y, e. En el pasillo. Entre otros metodos, un metodo accesible y aceptable para corregir este riesgo es reparar de nuevo el techo cemento y compuesto sellador.
6A0001
- Issued
- Abate by
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: At the establishment scretaries office entrance: An on/off light control 110/120 volts interrupter at 56 inches from the floor level was observed in which percolated pluvial entered through the wireway, accumulated on its base with runoff to the floor, exposing the employees to the hazard electric shock and or electrocution. Among other methods, one feasible and acceptable abatement method to correct this hazard is to seal the wireway and renew the damaged interrupter. A la entrada de la oficina de las secretarias del establecimiento: Un interruptor de control de luz encendido/apagado, de 110/120 voltios, a 56 pulgadas del nivel del piso, fue observado en el cual pluvial percolado entro atraves del conducto de los cables, se acumulo en la base con escurrimiento hacia el piso, exponiendo a los empleados al riesgo de sacudida electrica y/o electrocucion. Entre otros metodos, un metedo accesible y aceptable para corregir este riesgo es sellar el conducto de los cbles y reemplazar el interruptor danado.ptor
6A0001
- Issued
- Abate by
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: At the establishment: It were observed three (3) instances in which concrete sections of the ceiling of a square feet size menace to collapse and fall from ten (10) feet height; exposing the employees to the hazard of head and body traumas and or serious injuries: a. At the office of the regional director secretary sanitary facility; b. At the collector's office sanitary facility and, c. At the secretaries office sanitary facility. Among other methods, one feasible and acceptable abatement method to correct this hazard is to restore anew the ceiling with concrete. En el establecimiento: Se observaron tres (3) casos en los cuales secciones de empenetado de cemento del techo interior de un pie cuadrado en tamano amenazaban con colapsarse y caer desde diez (10) pies de altura; exponiendo a los empleados al riesgo de traumas y lesiones serias de la cabeza y el cuerpo: a. En la facilidad sanitaria de la oficina de la secretaria del director regional; b. En la facilidad sanitaria de la oficina de la recaudadora y, c. En la facilidad sanitaria de la oficina de las secretarias. Entre otros metodos, un metodo accesible y aceptable para corregir este riesgo es reparar de nuevo el techo interior con hormigon.
6A0001
- Issued
- Abate by
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: ANSI A132.1-1973 Section 7.3.1. The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: ANSI A132.1-1973 Seccion 7.3.1. El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: At the establishment: The luminaires on the second floor walkway were not functioning, creating a dark space where the employees were exposed to the hazard of slippings and or strippings with the resultant of body traumas and or injuries. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the luminaires or to provide a separate perimeter lighting system. En el establecimiento: Las luminarias en el pasillo del segundo piso no estaban funcionando, creandose un espacio obscuro donde los empleados estaban expuestos al riesgo de resbalones y/o tropezones con la resultante de traumas y/o lesiones del cuerpo. Entre otros metodos, un metodo accesible y aceptable para corregir este riesgo es reemplezar de nuevo las luminarias o proveer un sistema separado de alumbrado del perimetro.
1910.157 C04
- Issued
- Abate by
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in PR
SAN JUAN, PR—2026-07-16
U.S. DEPARTMENT OF AGRICULTURE-FOREST SERVICE
PONCE, PR—2026-07-15
CENTROS SOR ISOLINA FERRE INC
PONCE, PR—2026-07-15
FC CONSTRUCTION LLC
PONCE, PR—2026-07-15
HECTOR M. RIVERA
SAN JUAN, PR—2026-07-15
MUNICIPIO DE SAN JUAN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 126951409.