Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WALTON TOWERS INCORPORATED

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of WALTON TOWERS INCORPORATED in COYLE & CURTAIN ROADS, CHARLEROI, PA 15022 (NAICS 000000). OSHA activity number 17837188.

Watch Walton Towers Incorporated — free Get an email when a new federal OSHA severe-injury report for Walton Towers Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
COYLE & CURTAIN ROADS
City
CHARLEROI
State
PA
ZIP
15022
Mailing
RD 1 BOX 148-B, HERSHEY, PA 17033
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1791
Employees
4
Ownership type
A
Industry flags
Construction safety.

7 citations on file for this inspection.

5(a)(1)

Serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $400.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) Microwave tower, west side parking lot of West Penn Power Company,
Charleroi, PA; employees constructing a microwave tower were
permitted to ride the headache ball, hook and/or the load, exposing
themselves to a fall hazard of 80 feet.
A feasible and useful method to correct this hazard, among other methods
is to prohibit the employees from riding the load, headache ball or
hook.

1926.20 B01

Serious 1 instance 4 exposed
Issued
Abate by

5(a)(1)

Serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $200.00 · Current $200.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
%%
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) Truck mounted power winches - west side parking lot of Penn Power
Company.
A feasible and useful method to correct the hazard, among other methods,
is to keep a written record of the monthlyinspections made on the
ropes and brakes.

5(a)(1)

Serious 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $250.00 · Current $250.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
%%
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) Truck mounted winches, west side parking lot, a complete inspection
of the hoist was not performed at intervals as generally defined in
ANSI B30.7 1971-72.1.1.b.2 depending upon its activity, severity of
service and environment or as specifically indicated below:
1) The notches on the winch clutch locking system was worn
2) The clutch pull rod was bent.
3) The dogs in the clutch engaging system was worn.
4) A wad of grease was on a section of the dogs when engaged.
A feasible and useful method to correct this hazard, among other methods
is to replace the dogs, notch section and install newer rods to prevent
their bending.

5(a)(1)

Serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $300.00 · Current $300.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
%%
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) A truck mounted power winch west parking lot, a thorough inspection
of all ropes were not made at least once a month and a full written,
dated and signed report of rope condition kept on file and a
determination made as to whether future use of the rope would
constitute a safety hazard. The 3/8 inch wire rope 1500 ft. long
used to lift material was not installed in the wedge socket connected
to the hook so that the pulling part was directly in line with the
clevis pin. This will produce a sharp bend in the rope as it enters
the socket.
A feasible and useful method to correct this hazard, among others, is
to replace the dogs, notch section and install heavier rods to prevent
their bending.

1903.2 A01

Other-than-serious 1 instance 4 exposed
Issued
Abate by

1904.8

Other-than-serious 1 instance 4 exposed
Issued
Abate by

KGC, INC.