CHARLEROI, PA —
OSHA Inspection: WALTON TOWERS INCORPORATED
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of WALTON TOWERS INCORPORATED in COYLE & CURTAIN ROADS, CHARLEROI, PA 15022 (NAICS 000000). OSHA activity number 17837188.
Where did this inspection happen?
- Establishment
- WALTON TOWERS INCORPORATED
- Site address
- COYLE & CURTAIN ROADS
- City
- CHARLEROI
- State
- PA
- ZIP
- 15022
- Mailing
- RD 1 BOX 148-B, HERSHEY, PA 17033
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1791
- Employees
- 4
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $400.00 · Current $400.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Microwave tower, west side parking lot of West Penn Power Company, Charleroi, PA; employees constructing a microwave tower were permitted to ride the headache ball, hook and/or the load, exposing themselves to a fall hazard of 80 feet. A feasible and useful method to correct this hazard, among other methods is to prohibit the employees from riding the load, headache ball or hook.
1926.20 B01
- Issued
- Abate by
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $200.00 · Current $200.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Truck mounted power winches - west side parking lot of Penn Power Company. A feasible and useful method to correct the hazard, among other methods, is to keep a written record of the monthlyinspections made on the ropes and brakes.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $250.00 · Current $250.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Truck mounted winches, west side parking lot, a complete inspection of the hoist was not performed at intervals as generally defined in ANSI B30.7 1971-72.1.1.b.2 depending upon its activity, severity of service and environment or as specifically indicated below: 1) The notches on the winch clutch locking system was worn 2) The clutch pull rod was bent. 3) The dogs in the clutch engaging system was worn. 4) A wad of grease was on a section of the dogs when engaged. A feasible and useful method to correct this hazard, among other methods is to replace the dogs, notch section and install newer rods to prevent their bending.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $300.00 · Current $300.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) A truck mounted power winch west parking lot, a thorough inspection of all ropes were not made at least once a month and a full written, dated and signed report of rope condition kept on file and a determination made as to whether future use of the rope would constitute a safety hazard. The 3/8 inch wire rope 1500 ft. long used to lift material was not installed in the wedge socket connected to the hook so that the pulling part was directly in line with the clevis pin. This will produce a sharp bend in the rope as it enters the socket. A feasible and useful method to correct this hazard, among others, is to replace the dogs, notch section and install heavier rods to prevent their bending.
1903.2 A01
- Issued
- Abate by
1904.8
- Issued
- Abate by
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 17837188.