Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PEMM CORP.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of PEMM CORP. in R.D. 1, BOX 130A, COLD SPRING, NY 10516 (NAICS 000000). OSHA activity number 300524543.

Watch Pemm Corp. — free Get an email when a new federal OSHA severe-injury report for Pemm Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
PEMM CORP.
Site address
R.D. 1, BOX 130A
City
COLD SPRING
State
NY
ZIP
10516
Mailing
R.D. 1, BOX 130A, COLD SPRING, NY 10516
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
8711
Employees
10
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1570.00 Reduced
Section 5(a)(1) or in the alternative Section 1910.307 (b) of the
Occupational Safety and Health
Act of 1970:  The employer did not furnish employment and a place of
employment which were
free from recognized hazards that were causing or likely to cause death or
serious physical harm
to employees in that employees were exposed to: a fire hazard from not
removing all sources
of ignition from the area before starting a test process that involved
using heptane and nitrogen:
(a)11/18/96 thru 11/20/96, Pemm Corp: Employees were testing a process that
involved pumping heptane and nitrogen through a plexiglass column. They
were
pumping the mixture through a 10ft high plexiglass column at different
pressures
and mixing it with nitrogen when it started spraying out of the top hose
connection.When the mixture reached a nearby halogen light the heptane
ignited.
The fire then spread rapidly throughout the entire facility.
Abatement Notes:
Among other methods, one feasible method to reduce this hazard is to
establish and enforce
adequate safe operating procedures such as:
1.Before using any highly flammable products considerations to be taken in
this
process are: temperatures,pressures,the presence of co-reagents,and means
of
ignition,etc. Sources of ignition to be eliminated, include, but are not
limited to,
the following: open flames, cigarettes, matches, Hot surfaces, sparking
electrical
contacts and static electricity and others.
2.Training shall be provided to all employees prior to any use of or
testing of any
processes that involve the use of any highly flammable or combustible
products.
Recent events (2)
  • — I (S) $1570.00
  • — Z (S) $2100.00

1910.1200 G01

Serious Gravity 05 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1050.00 · Current $790.00 Reduced
Recent events (2)
  • — I (S) $790.00
  • — Z (S) $1050.00

1910.1200 H01

Serious Gravity 05 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1050.00 · Current $790.00 Reduced
Recent events (2)
  • — I (S) $790.00
  • — Z (S) $1050.00

KGC, INC.