SANTURCE, PR —
OSHA Inspection: QUALITY BOAT SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUALITY BOAT SERVICES in STOP 10, FERNANDEZ JUNCOS AVENUE, SANTURCE, PR 00909 (NAICS 000000). OSHA activity number 300655917.
Where did this inspection happen?
- Establishment
- QUALITY BOAT SERVICES
- Site address
- STOP 10, FERNANDEZ JUNCOS AVENUE
- City
- SANTURCE
- State
- PR
- ZIP
- 00909
- Mailing
- 667 PONCE DE LEON AVENUE # 343, SAN JUAN, PR 00907
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3732
- Employees
- 4
- Ownership type
- A
- Industry flags
- Maritime safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $1000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck and/or caught by/between a suspended load: a.At the worksite, it was documented that an employee places wood blocks, to initially support a boat before towers (in the form of tripods) are also placed to support the boat. Once the boat is lowered to the blocks, if modification to the location of the blocks is merited, the employee rearranges the blocks position. While relocating the blocks, the boat is suspended in the air by a Tami "ROPCO" lift while the employee is under the suspended load. Among others, feasible and acceptable abatement methods to correct this condition are to: 1. Properly support the load before work is begun. 2. The boat could be lowered into a cradle. 3. The blocks may be placed in a preselected location to avoid the need for an employee to rearrange them, therefore eliminating the exposure to the suspended load. NOTE:Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19.
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $1000.00
1915.156 A
- Issued
- Abate by
- Penalty
- Initial $600.00 · Current $600.00
More inspections at QUALITY BOAT SERVICES
SANTURCE, PR—1999-03-02 00:00:00
QUALITY BOAT SERVICES
SANTURCE, PR—1996-05-29 00:00:00
QUALITY BOAT SERVICES
SANTURCE, PR—1994-09-02 00:00:00
QUALITY BOAT SERVICES
View QUALITY BOAT SERVICES's full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in PR
SAN JUAN, PR—2026-07-16
U.S. DEPARTMENT OF AGRICULTURE-FOREST SERVICE
PONCE, PR—2026-07-15
CENTROS SOR ISOLINA FERRE INC
PONCE, PR—2026-07-15
FC CONSTRUCTION LLC
PONCE, PR—2026-07-15
HECTOR M. RIVERA
SAN JUAN, PR—2026-07-15
MUNICIPIO DE SAN JUAN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300655917.