Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DEPT OF TRANSPORTATION / USCG

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEPT OF TRANSPORTATION / USCG in HQTRS 2401 HAWKINS PT. RD., BALTIMORE, MD 21226 (NAICS 000000). OSHA activity number 301463378.

Watch Dept OF Transportation / Uscg — free Get an email when a new federal OSHA severe-injury report for Dept OF Transportation / Uscg is published. One employer, no account, unsubscribe in one click.
Site address
HQTRS 2401 HAWKINS PT. RD.
City
BALTIMORE
State
MD
ZIP
21226
Mailing
2401 HAWKINS POINT RD., BALTIMORE, MD 21226
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3731
Employees
550
Ownership type
D
Industry flags
Maritime safety.

28 citations on file for this inspection.

1910.178 M05 I

Serious Gravity 05 3 instances 15 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.212 A03 II

Serious Gravity 10 4 instances 1 exposed
Issued
Abate by

1910.212 B

Other-than-serious Gravity 02 1 instance 1 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (S)

1910.213 B03

Serious Gravity 03 1 instance 1 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.242 B

Other-than-serious Gravity 03 1 instance 1 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (S)

1910.253 B04 III

Serious Gravity 03 1 instance 1 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.12 A01 I

Deleted Serious Gravity 10 1 instance 100 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.12 B01I

Deleted Serious Gravity 10 1 instance 100 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.12 B01II

Deleted Serious Gravity 10 1 instance 100 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.12 C01I

Deleted Serious Gravity 10 1 instance 100 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.12 C01II

Deleted Serious Gravity 10 1 instance 100 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.12 D01

Deleted Serious Gravity 10 1 instance 100 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.52 A04

Other-than-serious Gravity 02 1 instance 50 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (S)

1915.52 B02

Deleted Serious Gravity 02 1 instance 50 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.55 E01

Deleted Serious Gravity 02 3 instances 50 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.55 E04

Deleted Serious Gravity 02 2 instances 100 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.71 J01

Serious Gravity 10 2 instances 15 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.71 K01

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.71 K05

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.73 B

Serious Gravity 02 3 instances 10 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.73 F

Deleted Serious Gravity 02 2 instances 10 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.77 C

Serious Gravity 05 1 instance 10 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.93 A01

Deleted Serious Gravity 02 1 instance 50 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1915.115 A01

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (S)

1915.131 G

Other-than-serious Gravity 02 1 instance 50 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (S)

1915.151 B01

Serious Gravity 03 2 instances 5 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1960.8 A

Serious Gravity 10 1 instance 50 exposed
Issued
Abate by
Section 5(a)(1) of the Occupational Safety and Health Act of 1970
reference Section 4-3.1.3.(l)
American National Standards Institute B30.4-1973 Safety Standards for
Portal, Tower, and Pillar
Cranes: Cranes shall not be operated when wind speeds exceed 45 miles per
hour or lower
velocities when recommended by the manufacturer.
USCG Yard, pier 1 - Portal tower cranes are not
tied-down when specified wind speeds are exceeded.  The USCG has a
policy that requires cranes to be tied-down when winds are steady
between 35 and 40 MPH.  Wind indicating devices are located in each
tower crane.  Foreman and operators are knowledgeable of the policy.
However, foreman interviewed stated they allow crane operators to use
their own discretion when shutting-down the crane.  On this day the
foreman said the operators were getting readings of 50 and 55 MPH,
but the crane continued to operate.  The foreman said that with a
heavy lift the cranes are not as likely to blow over.
Recent events (2)
  • — I (S)
  • — Z (S)

1915.99 G02 IB

Deleted Other-than-serious Gravity 01 1 instance 50 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (O)

View DEPT OF TRANSPORTATION / USCG's full OSHA safety record →