SANFORD, NC —
OSHA Inspection: CHARLEY J. SMITH DBA C & S BUILDERS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHARLEY J. SMITH DBA C & S BUILDERS in 1707 SOUTH HORNER BLVD., SANFORD, NC 27330 (NAICS 000000). OSHA activity number 302124300.
Where did this inspection happen?
- Establishment
- CHARLEY J. SMITH DBA C & S BUILDERS
- Site address
- 1707 SOUTH HORNER BLVD.
- City
- SANFORD
- State
- NC
- ZIP
- 27330
- Mailing
- 4580 WOMBLE RD., NASHVILLE, NC 27856
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1751
- Employees
- 3
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
3 citations on file for this inspection.
95012901
- Issued
- Abate by
- Penalty
- Initial $350.00 · Current $350.00
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to crush injuries: a)jobsite -- on or about 5:00 PM on 07/08/98, employees were installing 44' 5" long and 49' 5" long 2X4/2X6 parallel chord trusses on a 3750 square foot, 1 story building, when the roof trusses collapsed. Temporary bracing was only in place on both truss ends at the exterior walls and 1 location in the middle of the trusses. One feasible method of abatement, among others, is to follow the Truss Plate Institute HIB-91 Summary Sheet commentary and recommendations for handling and bracing metal plate connected trusses. Recommended temporary brace spacing is 6' for trusses 32'- 48' long, and 5' for trusses 40' - 60' long.
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $250.00 · Current $250.00
1926.21 B02
- Issued
- Abate by
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in NC
KERNERSVILLE, NC—2026-07-15
161552 - EDC, INC.
FRANKLINTON, NC—2026-07-15
161551 - LINDSAY PRECAST, LLC
RALEIGH, NC—2026-07-14
161550 - SUNRISE SENIOR LIVING MANAGEMENT, INC.
LAURINBURG, NC—2026-07-14
161549 - AMERICAN WOOD FIBERS, INC.
RURAL HALL, NC—2026-07-14
161546 - CAVERT WIRE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302124300.