Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SANTA FE DOOR STORE INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SANTA FE DOOR STORE INC in 2500 SECOND ST SW, ALBUQUERQUE, NM 87102 (NAICS 000000). OSHA activity number 302270798.

Watch Santa FE Door Store INC — free Get an email when a new federal OSHA severe-injury report for Santa FE Door Store INC is published. One employer, no account, unsubscribe in one click.
Site address
2500 SECOND ST SW
City
ALBUQUERQUE
State
NM
ZIP
87102
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
2431
Employees
28
Ownership type
A
Industry flags
Manufacturing safety.

13 citations on file for this inspection.

90005 A

Serious Gravity 01 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $600.00
Section 50-9-5(A), NMSA 1978 (New Mexico Occupational Health and Safety
Act):  Every
employer shall furnish to each of his employees employment and a place of
employment which
are free from recognized hazards that are causing or are likely to cause
death or serious physical
harm to his employees.
PVC schedule 40 pipe was being used to distribute compressed air to the
southern half
of the building.  The use of PVC pipe for the distribution of compressed
gas has been
prohibited by:
American National Standards Institute/American Society of Mechanical
Engineers
Standard B31.8-1986, Gas Transmission and Distribution Piping Systems
Standard, Sections 842.32, 842.43 and 849.52
American Society for Testing Materials D1785-86, Standard Specifications
for
Polyvinyl Chloride Plastic Pipe, Schedules 40, 80, and 120; and D2513-86a,
Standard Specification for Thermoplastic Gas Pressure Piping Systems.
Acceptable, and feasible means of abatement include, removing the PVC pipe
and
replacing with an approved type (some ABS materials, cast iron, etc.) or
enclosing the
pipe with an enclosure that is of sufficient strength to provide
protection for the existing
PVC pipe.
Date Corrected                  Describe Corrective  Action :

1910.213 D01

Serious Gravity 03 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1000.00 · Current $1000.00

1910.213 R04

Serious Gravity 02 1 instance 4 exposed
Issued
Abate by

1910.215 A02

Serious Gravity 01 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $600.00

1910.215 A04

Serious Gravity 02 2 instances 2 exposed
Issued
Abate by

1910.215 B09

Serious Gravity 01 2 instances 2 exposed
Issued
Abate by

1904.2 A

Other-than-serious Gravity 01 1 instance 28 exposed
Issued
Abate by

1910.157 E03

Other-than-serious Gravity 01 3 instances 4 exposed
Issued
Abate by

1910.157 E01

Other-than-serious Gravity 01 1 instance 4 exposed
Issued
Abate by

1910.213 H04

Other-than-serious Gravity 01 2 instances 2 exposed
Issued
Abate by

1910.213 P04

Other-than-serious Gravity 01 2 instances 4 exposed
Issued
Abate by

1910.303 G02 I

Other-than-serious Gravity 01 4 instances 4 exposed
Issued
Abate by

1910.304 A02

Other-than-serious Gravity 01 1 instance 4 exposed
Issued
Abate by

View SANTA FE DOOR STORE INC's full OSHA safety record →