OSHA Inspection: Y.P. EXTERIOR RESTORATIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of Y.P. EXTERIOR RESTORATIONS, INC. in 4100 FREEMANSBURG AVENUE, EASTON, PA 18045 (NAICS 000000). OSHA activity number 302336714.

Watch Y.P. Exterior Restorations, INC. — free Get an email when a new federal OSHA severe-injury report for Y.P. Exterior Restorations, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4100 FREEMANSBURG AVENUE
City
EASTON
State
PA
ZIP
18045
Mailing
RD 3, BOX 3646, BERWICK, PA 18603
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1761
Employees
4
Ownership type
A
Industry flags
Construction safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1500.00 · Current $750.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to a struck-by hazard from a falling load:
a) Manor Care/Arden Courts site - A CORMACH knuckleboom crane was used to
hoist
bundles of roofing insulation from the bed of truck trailers to the roof
of the structure.
Rigging for the load consisted of synthetic web slings and 2" X 4"
(nominal) boards.
The 2" x 4" boards, used as a structural component of the lifting device,
were not
designed to withstand the forces imposed by its rated load, with a minimum
design factor
of 3, based on yield strength of the material. (Refer ANSI B30.20)
ABATEMENT NOTE:  One feasible and acceptable method to abate this hazard
is to use
rigging equipment and devices specifically constructed and approved for
such purposes.
Abatement certification and documentation required within 10 days after
abatement date.
The certification shall include a statement that abatement is complete,
date and method of
abatement, and states employees and their representatives were informed of
this abatement.
Abatement documentation shall  include documents demonstrating that
abatement is
complete, such as evidence of the purchase or repair of equipment,
photographic or video
evidence of abatement or other written records.
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

1926.501 B03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1500.00 · Current $750.00 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by

KGC, INC.