OSHA Inspection: JOULE TECHNICAL
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of JOULE TECHNICAL in ENGELHARD CORP. 1057 LOWER SOUTH ST., PEEKSKILL, NY 10566 (NAICS 000000). OSHA activity number 302803317.
Where did this inspection happen?
- Establishment
- JOULE TECHNICAL
- Site address
- ENGELHARD CORP. 1057 LOWER SOUTH ST.
- City
- PEEKSKILL
- State
- NY
- ZIP
- 10566
- Mailing
- 1245 US ROUTE 1 SOUTH, EDISON, NJ 08837
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7389
- Employees
- 13
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $2500.00 Reduced
1430
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of dermal, eye, and inhalation exposures to titanium oxychloride resulting from an uncontrolled release of titanium oxychloride at Pump House 9A: a)Engelhard Corporation, 1057 Lower South Street, Peekskill,NY 10566. In the alley way between Buildings 4 and 9: Employees were exposed to the hazard of dermal, eye, and inhalation exposure to titanium oxychloride resulting from an uncontrolled release of titanium oxychloride: The titanium oxychloride piping system, on the suction side of pump P-3THCL, was deficient in that: (1) The employer did not utilize all necessary piping components in the construction of the piping system. Specifically, a kynar flange connection was used as a coupling and not as a flange connection. This portion of the piping system was missing a kynar flange connection, gasket, and bolting on or about 1/4/00. (2) The employer did not employ a recognized and accepted method of joining two different size pipe sections together (i.e. using a reducer). Specifically, glue was used to fill in the space that existed between a one and one-half (1 1/2) inch pipe and a two (2) inch pipe that were fit together. In addition, one of the pipe sections was made of Kynar which does not accept a glue bond, on or about 1/4/00. Among other methods, one feasible and accepted abatement method to correct this hazard is to construct, install, and inspect the piping system in accordance with the following established construction, installation, and inspection standards of ANSI/ASME B31.3- 1999 Process Piping and the NIBCO Inc. Thermoplastic Piping Technical Manual (PVC, CPVC, PP, PVDF) - Publication 7-140-C dated 1994. 1.Chapter VI - Inspection, Examination, and Testing, Paragraph 340 Inspection, Paragraph 340.2 - Responsibility for Inspection. 2.Chapter VII - Nonmetallic Piping and Piping Lined with Nonmetals, Paragraph A308 - Flanges, Blanks, Flange Facings,and Gaskets, Paragraph A308.2 - Nonmetallic Flanges, Paragraph A308.2.1(a). 3.Chapter VII - Nonmetallic Piping and Piping Lined with Nonmetals, Paragraph A328 - Bonding of Plastics. 4.Chapter VII - Part 10 INSPECTION, EXAMINATION, TESTING, Paragraph A341 Examination, Paragraph A342 Examination Personnel, Paragraph A343 Examination Procedures, Paragraph A344 Types of Examination, Paragraph A345 Testing 5. NIBCO Inc. Thermoplastic Piping Technical Manual (stated above). NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.ce
Recent events (2)
- — I (S) $2500.00
- — Z (S) $4500.00
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302803317.