ALBUQUERQUE, NM —
OSHA Inspection: SUNRAY CONSTRUCTION/CUSTOM WOODWORKS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SUNRAY CONSTRUCTION/CUSTOM WOODWORKS in 523-A RANKIN ROAD NE, ALBUQUERQUE, NM 87107 (NAICS 000000). OSHA activity number 303403505.
Where did this inspection happen?
- Establishment
- SUNRAY CONSTRUCTION/CUSTOM WOODWORKS
- Site address
- 523-A RANKIN ROAD NE
- City
- ALBUQUERQUE
- State
- NM
- ZIP
- 87107
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2599
- Employees
- 4
- Ownership type
- A
Citations
20 citations on file for this inspection.
90005 A
- Issued
- Abate by
- Penalty
- Initial $450.00 · Current $150.00 Reduced
General-duty citation text
THE CITATIONS ISSUED ON JUNE 20, 2001, ARE HEREBY AMENDED TO READ: Section 50-9-5(A), NMSA 1978 (New Mexico Occupational Health and Safety Act): Every employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees. Employees in the large and small shops are exposed to the hazards associated with the use of Schedule 40 PVC pipe for delivery of compressed air. Mode of failure for this type of piping is explosion with sharp projectiles. Use of Schedule 40 PVC is contrary to: Sections 842.32, 842.43 and 949.52(b) of the American National Standards Institute/ American Society of Mechanical Engineers (ANSI/ASME) Standards B31.8-1986, Gas Transmission and Distribution Piping Systems Standard; American Society for Testing Materials (ASTM) D1785-86, Standard Specifications for Polyvinyl Chloride Plastic Pipe, Schedules 40, 80 and 120; and ASTM D2513-86a, Standard Specification for Thermoplastic Gas Pressure Piping Systems. Proof of abatement: Date Corrected Describe Corrective Action :
Recent events (2)
- — A (S) $150.00
- — Z (S) $450.00
1910.37 K02
- Issued
- Abate by
- Penalty
- Initial $200.00 · Current $50.00 Reduced
Recent events (2)
- — A (S) $50.00
- — Z (S) $200.00
1910.37 Q01
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.94 C03 IIIA
- Issued
- Abate by
- Penalty
- Initial $150.00 · Current $100.00 Reduced
Recent events (2)
- — A (S) $100.00
- — Z (S) $150.00
1910.107 B01
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.107 D09
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.107 E02
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.107 G02
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $100.00
Recent events (2)
- — A (O)
- — Z (S) $100.00
1910.178 L
- Issued
- Abate by
- Penalty
- Initial $450.00 · Current $225.00 Reduced
Recent events (2)
- — A (S) $225.00
- — Z (S) $450.00
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $450.00 · Current $100.00 Reduced
Recent events (2)
- — A (S) $100.00
- — Z (S) $450.00
1910.213 C01
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.213 C02
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.213 C03
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.219 D01
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.303 G01 I
- Issued
- Abate by
- Penalty
- Initial $150.00 · Current $50.00 Reduced
Recent events (2)
- — A (S) $50.00
- — Z (S) $150.00
1910.305 E01
- Issued
- Abate by
Recent events (2)
- — A (S)
- — Z (S)
1910.134 C01
- Issued
- Abate by
1910.141 D02 II
- Issued
- Abate by
1910.1200 E01
- Issued
- Abate by
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in NM
RIO RANCHO, NM—2026-07-15
PROFESSIONAL STUCCO & SERVICE INC.
RIO RANCHO, NM—2026-07-15
AAA ROOFING COMPANY
LAS CRUCES, NM—2026-07-06
U-HAUL COMPANY OF SOUTHERN NEW MEXICO
JAL, NM—2026-07-01
HELMERICH & PAYNE, IDC
ALBUQUERQUE, NM—2026-06-29
RECON BATTERY WAREHOUSE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303403505.