FT SAM HOUSTON, TX —
OSHA Inspection: DOD - U.S. ARMY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DOD - U.S. ARMY in BUILDING 1384, FT SAM HOUSTON, TX 78234 (NAICS 000000). OSHA activity number 304385149.
Where did this inspection happen?
- Establishment
- DOD - U.S. ARMY
- Site address
- BUILDING 1384
- City
- FT SAM HOUSTON
- State
- TX
- ZIP
- 78234
- Mailing
- 1212 STANLEY RD, FT SAM HOUSTON, TX 78234
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 9711
- Employees
- 30
- Ownership type
- D
Citations
1 citation on file for this inspection.
1960.8 A
- Issued
- Abate by
General-duty citation text
29 CFR 1960.8(a): The employer did not furnish each employee employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm: (a) At the inspection site, the employees were exposed to a Wet Bulb Globe Temperature (WBGT) 88oF to 93oF while performing housekeeping duties exposing the employees to heat stress. Means of feasible abatement include, but may not be limited to: (1) Make water available, without restrictions. (2) Train employees to recognize the hazards of heat stress; purpose and coverage of environmental and medical surveillance programs and the advantages of employees participation of the program and the first aid procedures for and the potential health effects of, heat stroke and especially the danger of using drugs, including therapeutic ones and alcohol in hot environment. (3) Wear cooler clothes. (4) Frequent breaks. (5) Increase mechanical and natural ventilation. (6) Use the American Conference of Governmental Industrial Hygienists (ACGIH) Screening Criteria for Heat Stress Exposure and Activities within Metabolic Rate Categories.
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304385149.