OSHA Inspection: PRECISE CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRECISE CONSTRUCTION, INC. in 1715 LITHIA PINECREST ROAD, VALRICO, FL 33596 (NAICS 000000). OSHA activity number 304986292.

Watch Precise Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Precise Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1715 LITHIA PINECREST ROAD
City
VALRICO
State
FL
ZIP
33596
Mailing
5026 TRENTON STREET, TAMPA, FL 33619
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1531
Employees
4
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $5600.00 · Current $3640.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment which
were free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees in that:
a. At the construction site of the Hernando Pain Clinic, located at 5193
Mariner Blvd in
Spring Hill, Florida. The 62 foot metal plate connected wood roof trusses
were installed
without bracing as required by HIB-91 Summary Sheet Commentary and
Recommendations for Handling, Installing and Bracing Metal Plate Connected
Wood
Trusses. The trusses were installed by using 1X3 wooden spacers with
inadequate lateral,
and ground bracing. A registered professional engineer was not consulted
with regards
to the temporary bracing arrangement for the 62 foot metal plate connected
wood trusses.
One feasible and acceptable abatement method to correct these hazards is
to install roof
trusses in accordance the Truss Plate Institutes recommendations which are
contained in
"HIB-91, Recommendations For Handling, Installing and Bracing Metal Plate
Connected
Wood Trusses". The truss manufacturer provides a copy of the "HIB-91
Summary Sheet"
with the delivery of the truss information and their Design Criteria
refers to the HIB-91
for proper handling, installing and bracing.  The Standard Building Code
also refers to
the HIB-91 for handling, installing and bracing of metal plate connected
wood trusses.
Violation observed on 18 January 02.
Recent events (2)
  • — I (S) $3640.00
  • — Z (S) $5600.00

View PRECISE CONSTRUCTION, INC.'s full OSHA safety record →