Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DYER VENTURES INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DYER VENTURES INC. in 2535 LAS VEGAS BLVD, SO., LAS VEGAS, NV 89109 (NAICS 000000). OSHA activity number 305005878.

Watch Dyer Ventures INC. — free Get an email when a new federal OSHA severe-injury report for Dyer Ventures INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DYER VENTURES INC.
Site address
2535 LAS VEGAS BLVD, SO.
City
LAS VEGAS
State
NV
ZIP
89109
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
7999
Employees
100
Ownership type
A
Industry flags
Manufacturing safety.

1 citation on file for this inspection.

618037501

Deleted Serious Gravity 03 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $875.00
Nevada Revised Statute 618.375(1):  The employer did not furnish
employment and a place of
employment which was free from recognized hazards that were causing or
likely to cause death
or serious physical harm to employees:
The employer failed to ensure fall protection training and methods
included practices which did
not expose employees to potential falls while utilizing fall arrest
systems:
b.Employees inspecting roller coaster rails protected themselves from
falling by
wrapping the lanyard around the five inch diameter rail structure and
tying it back
onto itself.  Employees were exposed to potential falls of 72 feet at the
loop
structure, and 225 feet at the tower structure of the roller coaster.
REFERENCE: ANSI Z359.1 - 1992, 7.2.5;  "A SUITABLE ANCHORAGE CONNECTOR
SHALL BE USED FOR RIGGING THE CONNECTION OF LANYARDS AND LIFELINES
TO STRUCTURAL MEMBERS.  LANYARDS AND LIFELINES SHALL NOT BE
WRAPPED AROUND STRUCTURAL MEMBERS AND CONNECTED BACK ONTO
THEMSELVES UNLESS A SUITABLE ANCHORAGE CONNECTION MEANS IS
INTEGRAL TO THEM."
ONE FEASIBLE MEANS OF ABATEMENT WOULD BE TO USE SUITABLE
ANCHORAGE CONNECTORS OR TO USE "TIE-BACK" LANYARDS WHICH
INCORPORATE AN ENGINEERED DESIGN AND MATERIAL AS AN INTEGRAL PART
OF THE FALL ARREST SYSTEM.
Recent events (2)
  • — I (S)
  • — Z (S) $875.00

KGC, INC.