LAS VEGAS, NV —
OSHA Inspection: AMALGAMATED BUILDING SERVICES, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of AMALGAMATED BUILDING SERVICES, INC. in 3790 LAS VEGAS BLVD., SOUTH, LAS VEGAS, NV 89109 (NAICS 561790). OSHA activity number 306124348.
Where did this inspection happen?
- Establishment
- AMALGAMATED BUILDING SERVICES, INC.
- Site address
- 3790 LAS VEGAS BLVD., SOUTH
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89109
- Mailing
- 3111 SOUTH VALLEY VIEW, SUITE Z-106, LAS VEGAS, NV 89102
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- SIC code (legacy)
- 7349
- Employees
- 2
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
618037501
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $300.00 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to his employees: The employer failed to ensure that place of employment was free from recognized hazards, as follows: a.New York New York Hotel and Casino, window cleaning operation, two employees were using anchor points which were not designed and approved for window cleaning. Roof parapet wall braces were used to tie off the work line and the personal lifeline. The braces were not designed for a 5000 pound minimum load or 4-to-1 safety factor. Reference: ANSI/IWCA I-14.1 - 2001, "Window Cleaning Safety", Section 3.9 and Section 9.1.1 (*): Building owners and window cleaning contractors shall not allow suspended work to be performed unless it has been determined that the building has provided, identified and certified anchorages complying with Section 9 or 10 for:independent safety lines; tie-backs for outriggers, parapet clamps and cornice hooks; primary support anchorages for powered and manual boatswain's chairs; primary support anchorages for rope descent systems; horizontal (rope) lines or lifelines; and wherever else required. (*) Anchorages shall be capable of sustaining a 5000 pound minimum load or 4-to-1 safety factor, whichever is greater, in any direction that a load may be applied. b.New York New York Hotel and Casino, window cleaning operations, employees were allowed to use a rope descent system on buildings where descents exceed 300 feet above grade. New York New York towers are in heights up to 451 feet. Reference: ANSI/IWCA I-14.1 - 2001, Window Cleaning Safety, Section 5.7.12: Operators of rope descent systems shall continuously monitor wind speed and weather conditions throughout the course of operation. Rope descent systems shall not be used for window cleaning when wind speeds become excessive in accordance with Section 3.7 of this standard. On descents higher than 130 feet (40m), provisions shall be made for stabilization. Such provisions may include: a) continuous, (Part B); b) intermittent, (Part B); c) work station (suction cups). Descent shall not exceed 300 feet (91m) above the grade unless the windows cannot be safely and practicably accessed by other means. c.New York New York Hotel and Casino, a written plan was not developed and readily available as required to inform window cleaners, the building owner, enforcement authorities and the emergency personnel of working conditions, known hazards, public protection, etc. Reference: ANSI/IWCA I-14.1 - 2001, Window Cleaning Safety, Section 1.7: A written plan developed by the window cleaning contractor or qualified person shall be provided that will inform the building owner or their operating agents when windows to be cleaned are located in areas where workers may utilize suspended equipment or; where workers are exposed to falls or other known hazards or; where the public may beexposed to overhead equipment operations. The plan shall include among its conditions the identification of hazardous areas, drop zones, safety features and areas requiring public protection. The plan shall be readily available for use by the building owner or their operating agents, window cleaners, enforcing authorities and emergency personnel. The use of a written plan applies to a dwelling house over 3 full stories high or occupied by more than 3 families. One feasible method of abatement is to have assurance from the building owner that the anchorages and fixtures permanently dedicated to the building are safe and maintained in compliance with the referenced standard and that all accepted safe practices for window cleaning included in the ANSI/ICWA I-14.1 - 2001 are followed.
Recent events (2)
- — I (O) $300.00
- — Z (O) $1500.00
More inspections at AMALGAMATED BUILDING SERVICES, INC.
LAS VEGAS, NV—2004-02-02 00:00:00
AMALGAMATED BUILDING SERVICES, INC.
LAS VEGAS, NV—2004-01-23 00:00:00
AMALGAMATED BUILDING SERVICES, INC.
LAS VEGAS, NV—2003-03-10 00:00:00
AMALGAMATED BUILDING SERVICES, INC.
LAS VEGAS, NV—2002-08-15 00:00:00
AMALGAMATED BUILDING SERVICES, INC.
View AMALGAMATED BUILDING SERVICES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561790)
EAU CLAIRE, WI—2026-07-10
MIDWEST POWER WASHING, LLC
TUCSON, AZ—2026-07-08
CPX2026XSS813X0009 - SKYTEK BUILDING SERVICES, L.L.C.
ROANOKE, VA—2026-07-07
UNDER ONE ROOF HOME LIQUIDATION AND ESTATE SERVICES, INC.
BREMERTON, WA—2026-07-02
WA317991921 - KITSAP POWER WASH LLC
EVERETT, WA—2026-07-01
WA317991922 - NATIONAL FACILITY CONTRACTORS LLC
More inspections in NV
RENO, NV—2026-07-16
DC MASONRY
CARSON CITY, NV—2026-07-16
LT BUILDERS
ZEPHYR COVE, NV—2026-07-16
DOLLAR TREE STORES, INC.
SPARKS, NV—2026-07-16
SYUFY ENTERPRISES
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306124348.