APPLETON, WI —
OSHA Inspection: T J CUSTOM BUILDING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of T J CUSTOM BUILDING in # 6 LIGHTNING DR, APPLETON, WI 54914 (NAICS 238160). OSHA activity number 306794231.
Where did this inspection happen?
- Establishment
- T J CUSTOM BUILDING
- Site address
- # 6 LIGHTNING DR
- City
- APPLETON
- State
- WI
- ZIP
- 54914
- Mailing
- 1142 AUTUMN DR., BRILLION, WI 54110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- SIC code (legacy)
- 1761
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $525.00 · Current $525.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to broken bones or death from improper use of a Rough Terrain forklift truck, platform: Elevated work platforms used with Rough Terrain Forklift Trucks are designed by the manufacturer must meet design, construction, and use requirements as outlined by ASME B56.6 Safety Standard for Rough Terrain Forklift Trucks Section 8.24 and other acceptable industry practices. (a) On or about December 29, 2003, employees of T J Custom Building, worked in an elevated platform suspended by a SkyTrak all-terrain lift which did not meet the design and use requirements of ASME B56.6 in the following areas: 1) The guardrail around the upper periphery of the platform was incomplete. 2) The platform did not have the maximum work load and empty weight information prominently marked. 3) The platform dimension exceeded in width more than 10 inches greater than the overall width of the truck on either side. Among other methds, feasible and accetable means to correct these hazards are to use a safer alternate method such as the use of a scaffold and/or a platform approved by the manufacturer meeting the requirements of ASME/ANSI B56.6, 2002 for attachments on rough terrain forklifts. Abatement Certification required.tion
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $525.00 · Current $525.00
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306794231.