ROANOKE RAPIDS, NC —
OSHA Inspection: BREWER RADIATOR SERVICE, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of BREWER RADIATOR SERVICE, INC. in 511 JULIAN R ALLSBROOK HWY, ROANOKE RAPIDS, NC 27870 (NAICS 811118). OSHA activity number 307552174.
Where did this inspection happen?
- Establishment
- BREWER RADIATOR SERVICE, INC.
- Site address
- 511 JULIAN R ALLSBROOK HWY
- City
- ROANOKE RAPIDS
- State
- NC
- ZIP
- 27870
- Mailing
- P.O. BOX 324, ROANOKE RAPIDS, NC 27870
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811118
- SIC code (legacy)
- 7539
- Employees
- 5
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
16 citations on file for this inspection.
95012901
- Issued
- Abate by
- Penalty
- Initial $125.00 · Current $100.00 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck by hazard: a)facility - where a floor-operated underhung crane was being used to move large radiators (up to 400-600 pounds) and the load ratings of the crane bridge and runways were not marked. REF: ASME B30.11-1998, Monorails and Underhung Cranes. b)facility - where a CM Valustar electric hoist (1 ton) was used to lift large radiators (up to 400-600 pounds) approximately 4 - 41/2 feet above the floor and a label displaying information concerning operating procedures was affixed to the hoist, load block, or controls. REF: ASME B30.16-1998, Overhead Hoists (Underhung). c)facility - where the hook supplied with the CM Valustar electric hoist did not have a latch to bridge the throat opening of the hook and the manufacturer's identification was not visible on the hook. REF: ASME B30.16-1998, Overhead Hoists (Underhung) and ASME B30.10-1999, Hooks. d)facility - where a mechanical lifting device was being used to lift large radiators (up to 400-600 pounds) and the device was not marked with the rated load and test reports for a rated load test were not available. REF: ASME B30.20-1999, Below-The-Hook Lifting Devices. ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO ENSURE THAT FREQUENT AND PERIODIC INSPECTIONS ARE CONDUCTED ON THE CRANE, HOIST, HOOK, AND LIFTING DEVICE. ENSURE THAT ALL COMPONENTS ARE MARKED AS REQUIRED. DISCONTINUE PAINING THE HOOK FOR CORROSION CONTROL AS ANY CRACKS OR DEFORMITIES MAY BE MASKED. ENSURE THAT THE CHAIN CONNECTED TO THE RADIATOR LIFTING DEVICE IS DESIGNED AND RATED FOR THE PURPOSE.
Recent events (2)
- — I (S) $100.00
- — Z (S) $125.00
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $125.00
Recent events (2)
- — I (S)
- — Z (S) $125.00
1910.133 A01
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 E01
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 F05 I
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 F05 II
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 G01
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.22 D01
- Issued
- Abate by
1910.157 C01
- Issued
- Abate by
1910.133 A05
- Issued
- Abate by
1910.176 B
- Issued
- Abate by
1910.253 B04 III
- Issued
- Abate by
1910.303 B02
- Issued
- Abate by
1910.305 G02 III
- Issued
- Abate by
1910.1025 D02
- Issued
- Abate by
1910.1025 L01 I
- Issued
- Abate by
More inspections in this industry (NAICS 811118)
JASPER, IN—2026-06-23
STERNBERG COLLISION REPAIR CENTER
YUBA CITY, CA—2026-06-17
DOVE AUTO GLASS
NASHVILLE, TN—2026-06-12
BLB MOTOS, LLC
CICERO, NY—2026-06-09
ADMAR SUPPLY COMPANY, INC.
GILBERT, AZ—2026-06-08
URX2026XMG193X0058 - LOENBRO LLC
More inspections in NC
KERNERSVILLE, NC—2026-07-15
161552 - EDC, INC.
FRANKLINTON, NC—2026-07-15
161551 - LINDSAY PRECAST, LLC
RALEIGH, NC—2026-07-14
161550 - SUNRISE SENIOR LIVING MANAGEMENT, INC.
LAURINBURG, NC—2026-07-14
161549 - AMERICAN WOOD FIBERS, INC.
RURAL HALL, NC—2026-07-14
161546 - CAVERT WIRE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307552174.